{"product_id":"9132-9133-portable-infrared-calibrator","title":"9132\/9133 Portable Infrared Calibrator","description":"\u003cp\u003eFluke Calibration blackbody calibrators deliver the accuracy and reliability for precise calibration of infrared thermometers and thermal imagers.\u003c\/p\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003ch3\u003eReliable, Portable Blackbody Calibration for IR Thermometers and Imagers\u003c\/h3\u003e\u003cp\u003eFluke’s 9132 and 9133 infrared calibrators are designed to meet the precise needs of infrared thermometer and thermal imager users. These portable blackbody sources offer fast heating and cooling, stable temperatures, and radiometric accuracy—making them ideal for field and lab environments alike.\u003c\/p\u003e\u003ch3\u003eFluke 9132 – High-Temperature Blackbody Source (Up to 500 °C)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for IR calibrations above ambient\u003c\/li\u003e\n\u003cli\u003eProvides a stable blackbody surface up to 500 °C (932 °F)\u003c\/li\u003e\n\u003cli\u003eShort heating and cooling times keep workflows efficient\u003c\/li\u003e\n\u003cli\u003eRadiometric calibration ensures measurement confidence across its entire range\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFluke 9133 – Low-Temperature Blackbody Source (–30 °C to 150 °C)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIdeal for calibrating IR thermometers at low temperatures\u003c\/li\u003e\n\u003cli\u003eReaches –30 °C (22 °F) in typical ambient conditions using solid-state cooling\u003c\/li\u003e\n\u003cli\u003eConvenient dry gas fitting on front bezel prevents ice buildup on the target\u003c\/li\u003e\n\u003cli\u003eOffers stable temperature control up to 160 °C (320 °F)\u003c\/li\u003e\n\u003cli\u003eHeats or cools from ambient to either extreme in approximately 15 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat is a Blackbody Calibrator?\u003c\/h3\u003e\u003cp\u003eA \u003cstrong\u003eblackbody calibrator\u003c\/strong\u003e (or blackbody source) is a device that emits thermal radiation with \u003cstrong\u003ehigh emissivity\u003c\/strong\u003e, typically near 1.0. This makes it behave closely to an ideal blackbody, emitting radiation according to Planck’s law.\u003c\/p\u003e\u003cp\u003eBlackbody calibrators are essential tools for ensuring the accuracy of:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInfrared thermometers\u003c\/li\u003e\n\u003cli\u003eThermal imagers\u003c\/li\u003e\n\u003cli\u003eNon-contact temperature measurement devices\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBy aiming a device under test at the precisely controlled blackbody target, users can \u003cstrong\u003everify and adjust readings\u003c\/strong\u003e to ensure accuracy and compliance with calibration standards.\u003c\/p\u003e\u003ch3\u003eSummary: Why Choose the 9132 or 9133?\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIdeal For\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9132\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 500 °C (932 °F)\u003c\/td\u003e\n\u003ctd\u003eHigh-temperature IR calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9133\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–30 °C to 160 °C (–22 °F to 320 °F)\u003c\/td\u003e\n\u003ctd\u003eLow-temperature IR calibration with fast transitions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eBoth units provide:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePortable, stable blackbody sources\u003c\/li\u003e\n\u003cli\u003eQuick heating and cooling times\u003c\/li\u003e\n\u003cli\u003eHigh emissivity targets for accurate infrared calibration\u003c\/li\u003e\n\u003cli\u003eConfidence backed by Fluke’s precision and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003eModels\u003cul\u003e\n\u003cli\u003e9132\u003c\/li\u003e\n\u003cli\u003e9133\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 9132\/9133 Portable Infrared Calibrator with Blackbody Source\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecifications\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9132\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9133\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e50°C to 500°C\u003cbr\u003e(122°F to 932°F)\u003c\/td\u003e\n\u003ctd\u003e–30°C to 150°C at 23°C ambient\u003cbr\u003e(–22°F to 302°F at 73°F ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C at 100°C\u003cbr\u003e(±0.9°F at 212°F)\u003cbr\u003e±0.8°C at 500°C\u003cbr\u003e(±1.4°F at 932°F)\u003c\/td\u003e\n\u003ctd\u003e±0.4°C (±0.72°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.1°C at 100°C\u003cbr\u003e(±0.18°F at 212°F)\u003cbr\u003e±0.3°C at 500°C\u003cbr\u003e(±0.54°F at 932°F)\u003c\/td\u003e\n\u003ctd\u003e±0.1°C (±0.18°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget size\u003c\/td\u003e\n\u003ctd\u003e57 mm (2.25 in)\u003c\/td\u003e\n\u003ctd\u003e57 mm (2.25 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget emissivity\u003c\/td\u003e\n\u003ctd\u003e0.95 (±0.02 from 8 to 14 mm)\u003c\/td\u003e\n\u003ctd\u003e0.95 (±0.02 from 8 to 14 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1°\u003c\/td\u003e\n\u003ctd\u003e0.1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating time\u003c\/td\u003e\n\u003ctd\u003e30 minutes (50°C to 500°C)\u003c\/td\u003e\n\u003ctd\u003e15 minutes (25°C to 150°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling time\u003c\/td\u003e\n\u003ctd\u003e30 minutes (500°C to 100°C)\u003c\/td\u003e\n\u003ctd\u003e15 minutes (25°C to –20°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComputer interface\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRS-232 I\/O included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e115 V AC (±10%), 3 A or\u003cbr\u003e230 V AC (±10%), 1.5 A,\u003cbr\u003eswitchable, 50\/60 Hz, 340 W\u003c\/td\u003e\n\u003ctd\u003e115 V AC (±10%), 1.5 A, or\u003cbr\u003e230 V AC (±10%), 1.0 A,\u003cbr\u003eswitchable, 50\/60 Hz, 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e102 x 152 x 178 mm\u003cbr\u003e(4 x 6 x 7 in )\u003c\/td\u003e\n\u003ctd\u003e152 x 286 x 267 mm\u003cbr\u003e(6 x 11.25 x 10.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg (4 lb)\u003c\/td\u003e\n\u003ctd\u003e4.6 kg (10 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eRadiometric calibration on the 9132\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003eData at 50°C, 100°C, 200°C, 250°C, 300°C, 400°C, and 500°C\u003c\/td\u003e\n\u003ctd\u003eData at –30°C, 0°C, 25°C, 75°C, 100°C, 125°C, and 150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"models-label\" class=\"tab-pane\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"9132","offer_id":54038940746022,"sku":"9132","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"9133","offer_id":54038940877094,"sku":"9133","price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/af62ba72-7f2e-4fb4-ac81-b108006b9914_original__size.jpg?v=1791380812","url":"https:\/\/nplab.shop\/products\/9132-9133-portable-infrared-calibrator","provider":"NP LAB","version":"1.0","type":"link"}