{"product_id":"9103-9140-field-dry-well","title":"9103\/9140 Field Dry-Well","description":"\u003cp\u003eIf you’ve been using dry-well calibrators for field work, you know there’s a lot more to a dry-well than its temperature range and stability.\u003c\/p\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePortable, fast, and accurate temperature sources for on-site calibration\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eExceptional Performance in a Compact Design\u003c\/h3\u003e\u003cp\u003eThe Fluke 9103 and 9140 Field Dry-Wells outperform the competition in nearly every category—\u003cstrong\u003eperformance, size, weight, ease of use, calibration simplicity, software integration, and price\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eEach unit features:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAdjustable \u003cstrong\u003eheating and cooling rates\u003c\/strong\u003e via the front panel\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eThermal switch actuation testing\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple-hole inserts\u003c\/strong\u003e for compatibility with a wide range of probe sizes\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFast Calibration with Minimal Downtime\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUnits are \u003cstrong\u003eeasy to calibrate\u003c\/strong\u003e without opening the case, reducing maintenance costs and downtime\u003c\/li\u003e\n\u003cli\u003eAll units include a \u003cstrong\u003eNIST-traceable calibration certificate at no additional charge\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-tested\u003c\/strong\u003e for accuracy and reliability before shipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSoftware Integration\u003c\/h3\u003e\u003cp\u003eFluke’s Interface-it software supports:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSet-point and ramp rate control\u003c\/li\u003e\n\u003cli\u003eReal-time temperature logging\u003c\/li\u003e\n\u003cli\u003eElectronic strip chart creation\u003c\/li\u003e\n\u003cli\u003eThermal switch test automation with data collection\u003c\/li\u003e\n\u003cli\u003eWindows-based interface with intuitive graphical controls\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWhether you need basic control or full automation, Fluke has a software solution ready.\u003c\/p\u003e\u003ch3\u003eFluke 9103 – Low-Temperature Field Dry-Well\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e Down to –25 °C (actual, not below ambient)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStability:\u003c\/strong\u003e ±0.02 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Accuracy:\u003c\/strong\u003e ±0.25 °C across full range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eReaches 0 °C in 8 minutes\u003c\/li\u003e\n\u003cli\u003eReaches 100 °C in 6 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eKey Advantage:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eMany competitors advertise –45 °C below ambient, which only reaches around –20 °C. The 9103 delivers a \u003cstrong\u003etrue –25 °C\u003c\/strong\u003e in standard room conditions—\u003cstrong\u003eno walk-in freezer required\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsert Options:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eChoose from four removable inserts to suit your calibration needs:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsert A:\u003c\/strong\u003e One well each from 1\/16” to 1\/2”\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsert B:\u003c\/strong\u003e Two wells each of 3\/8”, 1\/4”, and 3\/16” (ideal for comparison calibrations)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsert C:\u003c\/strong\u003e Six 1\/4” wells for multiple probe calibrations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsert D:\u003c\/strong\u003e Three pairs of metric-sized wells\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFluke 9140 – Mid-Temperature Field Dry-Well\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e 35 °C to 350 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStability:\u003c\/strong\u003e ±0.05 °C or better\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniformity:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e0.1 °C\u003c\/strong\u003e in small-diameter wells\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0.4 °C\u003c\/strong\u003e in largest-diameter wells\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed:\u003c\/strong\u003e Reaches max temperature in 12 minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e Weighs only 6 lbs, easily portable with one hand\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Accuracy:\u003c\/strong\u003e ±0.5 °C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFor improved calibration accuracy, use an \u003cstrong\u003eexternal thermometer\u003c\/strong\u003e alongside the built-in display.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsert Options:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThree removable inserts available to accommodate various probe sizes.\u003c\/p\u003e\u003ch3\u003eWhy Choose the 9103 or 9140?\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eStability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9103\u003c\/td\u003e\n\u003ctd\u003e–25 °C to 110+ °C\u003c\/td\u003e\n\u003ctd\u003e±0.02 °C\u003c\/td\u003e\n\u003ctd\u003e±0.25 °C\u003c\/td\u003e\n\u003ctd\u003eTrue sub-ambient performance without freezer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9140\u003c\/td\u003e\n\u003ctd\u003e35 °C to 350 °C\u003c\/td\u003e\n\u003ctd\u003e±0.05 °C\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C\u003c\/td\u003e\n\u003ctd\u003eLight, fast, and ideal for field portability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eBoth models are:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable\u003c\/strong\u003e for industrial and lab environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile\u003c\/strong\u003e with multiple insert options\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBacked by Fluke’s proven calibration technology\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003eModels\u003cul\u003e\n\u003cli\u003e9103\u003c\/li\u003e\n\u003cli\u003e9103-A\u003c\/li\u003e\n\u003cli\u003e9103-B\u003c\/li\u003e\n\u003cli\u003e9103-C\u003c\/li\u003e\n\u003cli\u003e9103-D\u003c\/li\u003e\n\u003cli\u003e9140\u003c\/li\u003e\n\u003cli\u003e9140-A\u003c\/li\u003e\n\u003cli\u003e9140-B\u003c\/li\u003e\n\u003cli\u003e9140-C\u003c\/li\u003e\n\u003cli\u003e9140-D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke Calibration 9103\/9140 Field Dry-Well\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecifications\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9103\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9140\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–25°C to 140°C\u003cbr\u003e(–13°F to 284°F)\u003cbr\u003eat 23°C ambient\u003c\/td\u003e\n\u003ctd\u003e35°C to 350°C\u003cbr\u003e(95°F to 662°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.25°C (holes greater than 1\/4\" [6.35mm]: ±1°C)\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (holes greater than 1\/4\" [6.35mm]: ±1°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.02°C at –25°C\u003cbr\u003e±0.04°C at 140°C\u003c\/td\u003e\n\u003ctd\u003e±0.03°C at 50°C\u003cbr\u003e±0.05°C at 350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell-to-well uniformity\u003c\/td\u003e\n\u003ctd\u003e±0.1°C between similarly sized wells\u003c\/td\u003e\n\u003ctd\u003e±0.1°C with similarly sized wells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating times\u003c\/td\u003e\n\u003ctd\u003e18 minutes from ambient to 140°C\u003c\/td\u003e\n\u003ctd\u003e12 minutes from ambient to 350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling times\u003c\/td\u003e\n\u003ctd\u003e20 minutes from ambient to –25°C\u003c\/td\u003e\n\u003ctd\u003e15 minutes from 350°C to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStabilization time\u003c\/td\u003e\n\u003ctd\u003e7 minutes\u003c\/td\u003e\n\u003ctd\u003e7 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmersion depth\u003c\/td\u003e\n\u003ctd\u003e124 mm (4.875 in)\u003c\/td\u003e\n\u003ctd\u003e124 mm (4.875 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInserts\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInsert A, B, C, or D included (specify when ordering)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside insert dimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e31.8 mm dia. x 124 mm (1.25 x 4.88 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComputer interface\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRS-232 included with free Interface-it software (Model 9930)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e115 V AC (±10%), 1.3 A or 230 V AC (±10%), 0.7 A, switchable, 50\/60 Hz, 150 W\u003c\/td\u003e\n\u003ctd\u003e115 V AC (±10%), 4.4 A or 230 V AC (±10%), 2.2 A, switchable, 50\/60 Hz, 500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e143 x 261 x 245 mm\u003cbr\u003e(5.63 x 10.25 x 9.63 in)\u003c\/td\u003e\n\u003ctd\u003e152 x 86 x 197 mm\u003cbr\u003e(6 x 3.375 x 7.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.7 kg (12 lb)\u003c\/td\u003e\n\u003ctd\u003e2.7 kg (6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNIST-traceable certificate\u003c\/td\u003e\n\u003ctd\u003eData at –25°C, 0°C, 25°C, 50°C, 75°C, 100°C, and 140°\u003c\/td\u003e\n\u003ctd\u003eData at 50°C, 100°C, 150°C, 200°C, 250°C, 300°C, and 350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"models-label\" class=\"tab-pane\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"9103","offer_id":54038928720166,"sku":"9103","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"9103-A","offer_id":54038928785702,"sku":"9103-A","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"9103-B","offer_id":54038928818470,"sku":"9103-B","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"9103-C","offer_id":54038928851238,"sku":"9103-C","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"9103-D","offer_id":54038928884006,"sku":"9103-D","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"9140","offer_id":54038928916774,"sku":"9140","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"9140-A","offer_id":54038928949542,"sku":"9140-A","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"9140-B","offer_id":54038928982310,"sku":"9140-B","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"9140-C","offer_id":54038929015078,"sku":"9140-C","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"9140-D","offer_id":54038929047846,"sku":"9140-D","price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/589f6241-d5d1-41db-819b-b108006b462f_original__size.jpg?v=1791380540","url":"https:\/\/nplab.shop\/products\/9103-9140-field-dry-well","provider":"NP LAB","version":"1.0","type":"link"}