{"product_id":"5615-secondary-reference-prt","title":"5615 Secondary Reference PRT","description":"\u003cp\u003eFluke Calibration 5615 secondary reference PRT offers ±0.012 °C accuracy at 0 °C, Inconel sheath and NVLAP certificate—ideal for lab or field work.\u003c\/p\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe 5615-12 (formerly Hart Scientific) is a Platinum Resistance Thermometer (PRT) with an Inconel™ 600 sheath that’s 305 mm (12 in) long and 6.35 mm (0.250 in) in diameter. It is a secondary reference temperature standard designed to bridge the gap between the highest laboratory standards and industrial or second-tier lab locations. It has accuracy of ± 0.012 °C at 0.01 °C.\u003c\/p\u003e\u003cp\u003eThe element is constructed of reference-grade platinum wire (99.999 % pure) for excellent stability. The wire is wound in a coil and placed in a mandrel where it’s uniformly supported in a manner that virtually eliminates hysteresis. The electrical configuration is a four-wire current-potential hookup that eliminate the effects of lead-wire resistance.\u003c\/p\u003e\u003cp\u003eThese Inconel™-sheathed probes have a fully supported sensing element, making them more durable than SPRTs. The element is protected in an ultrahigh-purity ceramic case with a hermetic glass seal to improve output stability by locking out moisture and contaminants.\u003c\/p\u003e\u003cp\u003eThis probe comes calibrated with ITS-90 coefficients, making it compatible with many excellent readout devices, including Fluke Calibration’s 1529 Chub-E4, 1560 Black Stack, and 1502A Tweener. It bridges the gap between a 100-ohm industrial RTD and an SPRT.\u003c\/p\u003e\u003cp\u003eFor those needing faster thermal response, or where diameter and immersion depth are problems, order the 5615-9 or 5615-6. These probes are excellent reference probes for comparison calibrations in a Fluke Calibration dry-well. The sheaths of the 5615-6 and 5615-9 are 4.76 mm (0.188 in) in diameter.\u003c\/p\u003e\u003cp\u003eA printout of sensor resistance is provided in 1 °C increments for each probe. The 5615-9 and 5615-12 are calibrated from –196 °C to 420 °C. The 5615-6 is calibrated to 300 °C.\u003c\/p\u003e\u003cp\u003eWe’ve tested many of the probes on the market. We’ve used them in our manufacturing facility and tested them in the lab, and this is an excellent secondary standards PRT. Other instruments on the market are priced much higher, have lower stability, or are of lower quality.\u003c\/p\u003e\u003cp\u003eRemember, these are reliable instruments and each probe comes with its own individual accredited calibration.\u003c\/p\u003e\u003cdiv\u003eModels\u003cul\u003e\n\u003cli\u003e5615-6-X\u003c\/li\u003e\n\u003cli\u003e5615-9-X\u003c\/li\u003e\n\u003cli\u003e5615-12-X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e“X” in a model number denotes the probe termination (e.g. A = INFO-CON for 914X, B = bare wire, D = 5-pin DIN, G = gold pins, J = banana plugs, L = mini spade lugs, M = mini banana plugs, P = INFO-CON for 1523\/1524, S = spade lugs). Please specify when enquiring.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications: 5615 Secondary Reference PRT\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e5615-12 and 5615-9: –200 °C to 420 °C\u003cbr\u003e5615-6: –200 °C to 300 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal resistance at 0 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω ± 0.10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0039250 Ω\/Ω\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eAccuracy\u003csup\u003e[1]\u003c\/sup\u003e\u003c\/strong\u003e\u003cbr\u003e \u003cbr\u003e \u003c\/td\u003e\n\u003ctd\u003e± 0.024 °C at –200 °C\u003cbr\u003e± 0.012 °C at 0 °C\u003cbr\u003e± 0.035 °C at 420 °CC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-term repeatability\u003csup\u003e[2]\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.009 °C at 0.010 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrift\u003csup\u003e[3]\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.007 °C at 0.010 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 mm (1.1 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.9 mm ± 3.3 mm from tip (0.27 in ± 0.13 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSheath dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e5615-6:\u003c\/strong\u003e 152 mm x 4.76 mm (6.0 in x 0.188 in)\u003cbr\u003e\u003cstrong\u003e5615-9:\u003c\/strong\u003e 229 mm x 4.76 mm (9.0 in x 0.188 in)\u003cbr\u003e\u003cstrong\u003e5615-12:\u003c\/strong\u003e 305 mm x 6.35 mm (12.0 in x 0.250 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSheath diameter tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.127 mm (± 0.005 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSheath material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInconel™ 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum insulation resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 MΩ at 23 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransition junction temperature range\u003csup\u003e[4]\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–50 °C to 200 °C\u003cbr\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransition junction dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e71 mm x 13 mm dia (2.8 in x 0.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMaximum immersion length\u003c\/strong\u003e\u003cbr\u003e \u003cbr\u003e \u003c\/td\u003e\n\u003ctd\u003e5615-6: 102 mm (4 in)\u003cbr\u003e5615-9: 178 mm (7 in)\u003cbr\u003e5615-12: 254 mm (10 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003csup\u003e[5]\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 seconds typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelf heating (in 0 °C bath)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mW\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLead-wire cable type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePTFE insulated with PTFE jacket, 22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLead-wire length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e183 cm (72 in or 6 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLead-wire temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–50 °C to 200 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003cbr\u003e \u003cbr\u003e \u003c\/td\u003e\n\u003ctd\u003eAccredited calibration included. Please see calibration uncertainty table and its explanation of changeable uncertainties.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003csup\u003e[1]\u003c\/sup\u003e Includes calibration and 100 hr drift (k=2)\u003cbr\u003e\u003cbr\u003e\u003csup\u003e[2]\u003c\/sup\u003e Three thermal cycles from min to max temp, includes hysteresis, 95 % confidence (k=2)\u003cbr\u003e\u003cbr\u003e\u003csup\u003e[3]\u003c\/sup\u003e After 100 hrs at max temp, 95 % confidence (k=2)\u003cbr\u003e\u003cbr\u003e\u003csup\u003e[4]\u003c\/sup\u003e Temperatures outside this range will cause irreparable damage. For best performance, transition junction should not be too hot to touch.\u003cbr\u003e\u003cbr\u003e\u003csup\u003e[5]\u003c\/sup\u003e Per ASTM E 644\u003c\/td\u003e\n\u003ctd\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCalibration Uncertainty\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eExpanded Uncertainty (k=2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e–196 °C\u003c\/td\u003e\n\u003ctd\u003e0.024 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e–38 °C\u003c\/td\u003e\n\u003ctd\u003e0.011 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 °C\u003c\/td\u003e\n\u003ctd\u003e0.010 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200 °C\u003c\/td\u003e\n\u003ctd\u003e0.018 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e420 °C\u003csup\u003e‡\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.029 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\n\u003cbr\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Calibration uncertainties depend on the uncertainties of the lab performing the calibration. Subsequent calibrations of this probe performed with different processes, at different facilities, or with changed uncertainty statements may state different uncertainties. †Lab code 200706-0 ‡5615-6 excluded\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"models-label\" class=\"tab-pane\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"5615-6-X","offer_id":54038944612646,"sku":"5615-6-X","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"5615-9-X","offer_id":54038944710950,"sku":"5615-9-X","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"5615-12-X","offer_id":54038944743718,"sku":"5615-12-X","price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/36e94b2e-81a6-445f-8f3b-b2a4016d38d3_original__size.jpg?v=1791381001","url":"https:\/\/nplab.shop\/products\/5615-secondary-reference-prt","provider":"NP LAB","version":"1.0","type":"link"}