{"product_id":"5608-5609-secondary-reference-prt","title":"5608\/5609 Secondary Reference PRT","description":"\u003cp\u003eFluke Calibration 5608\/5609 PRT probes are secondary reference standards for precise and stable temperature measurements.\u003c\/p\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe 5608 comes with a one-eighth inch (3.18 mm) diameter sheath in lengths of 9 inches or 12 inches. The 5609 comes with a one-quarter inch (6.35 mm) diameter sheath in lengths of 12 inches, 15 inches, and 20 inches; or with a 6 mm diameter in lengths of 300 mm, 400 mm, or 500 mm.\u003c\/p\u003e\u003cp\u003eWhen looking for improved response time and reduced stem effect in shallow immersion, look for small diameter probes, because the measurement error called stem effect is caused by the diameter of the stem rather than the length of the stem.\u003c\/p\u003e\u003cp\u003eBoth of these probes have Inconel™ sheaths and are made using a special manufacturing process, giving them great precision over a wide temperature range. The sensors for these probes are reference-grade platinum and feature four-wire connections with less noisy measurements than two-wire counterparts.\u003c\/p\u003e\u003cp\u003eAs standard, each probe includes its resistance value at the triple point of water. If calibration is desired, you can order an accredited calibration from our laboratory; lab code 200348-0. On the report of calibration, you’ll get the test data and the ITS90 calibration coefficients that you can easily input into any Fluke Calibration thermometer. If you order your probe with an smart connector, we’ll program the coefficients directly into your connector, which loads the coefficients for you when you plug it into our 1524 Handheld Thermometer.\u003c\/p\u003e\u003cdiv\u003eModels\u003cul\u003e\n\u003cli\u003e5608-9-X\u003c\/li\u003e\n\u003cli\u003e5608-12-X\u003c\/li\u003e\n\u003cli\u003e5609-12-X\u003c\/li\u003e\n\u003cli\u003e5609-20-X\u003c\/li\u003e\n\u003cli\u003e5609-300-X\u003c\/li\u003e\n\u003cli\u003e5609-400-X\u003c\/li\u003e\n\u003cli\u003e5609-500-X\u003c\/li\u003e\n\u003cli\u003e5609-9BND-X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e“X” in a model number denotes the probe termination (e.g. A = INFO-CON for 914X, B = bare wire, D = 5-pin DIN, G = gold pins, J = banana plugs, L = mini spade lugs, M = mini banana plugs, P = INFO-CON for 1523\/1524, S = spade lugs). Please specify when enquiring.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications: Secondary PRT with Calibration Options - 5608 and 5609\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e5608:\u003c\/strong\u003e –200 °C to 500 °C\u003cbr\u003e\u003cstrong\u003e5609:\u003c\/strong\u003e –200 °C to 670 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal resistance at 0.01 °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω ± 0.5 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0039250 Ω\/Ω\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eRelative Accuracy\u003csup\u003e[1]\u003c\/sup\u003e\u003c\/strong\u003e\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003c\/td\u003e\n\u003ctd\u003e± 0.007 °C at –200 °C\u003cbr\u003e± 0.008 °C at 0 °C\u003cbr\u003e± 0.020 °C at 420 °C\u003cbr\u003e± 0.027 °C at 660 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eShort-term repeatability\u003csup\u003e[2]\u003c\/sup\u003e\u003c\/strong\u003e\u003cbr\u003e \u003c\/td\u003e\n\u003ctd\u003e± 0.007 °C at 0.010 °C\u003cbr\u003e± 0.013 °C at max temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eDrift\u003csup\u003e[3]\u003c\/sup\u003e\u003c\/strong\u003e\u003cbr\u003e \u003c\/td\u003e\n\u003ctd\u003e± 0.01 °C at 0.010 °C\u003cbr\u003e± 0.02 °C at max temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHysteresis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.01 °C maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mm ± 5 mm (1.2 in ± 0.2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 mm ± 1 mm from tip (0.1 in ± 0.1 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSheath material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInconel™ 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMinimum insulation resistance\u003c\/strong\u003e\u003cbr\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e5608:\u003c\/strong\u003e 500 MΩ at 23 °C, 20 MΩ at 500 °C\u003cbr\u003e\u003cstrong\u003e5609:\u003c\/strong\u003e 500 MΩ at 23 °C, 10 MΩ at 670 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransition junction temperature range\u003csup\u003e[4]\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–50 ºC to 200 °C\u003cbr\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransition junction dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e71 mm x 12.5 mm (2.8 in x 0.49 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMinimum immersion length\u003csup\u003e[5]\u003c\/sup\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(\u0026lt;5\u0026gt;\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e5608:\u003c\/strong\u003e 80 mm (3.1 in)\u003cbr\u003e\u003cstrong\u003e5609:\u003c\/strong\u003e 100 mm (3.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum immersion length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 mm (12 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eResponse time\u003csup\u003e[5]\u003c\/sup\u003e\u003c\/strong\u003e\u003cbr\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e5608:\u003c\/strong\u003e 9 seconds typical\u003cbr\u003e\u003cstrong\u003e5609:\u003c\/strong\u003e 12 seconds typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eSelf heating (in 0 °C bath)\u003c\/strong\u003e\u003cbr\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e5608:\u003c\/strong\u003e 75 mW\/°C\u003cbr\u003e\u003cstrong\u003e5609:\u003c\/strong\u003e 50 mW\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLead-wire cable type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePTFE 24 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLead-wire length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 m (6 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLead-wire temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–50 °C to 250 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003cbr\u003e \u003cbr\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003csup\u003e[1]\u003c\/sup\u003e Includes short-term repeatability and 100 hr drift. Calibration will add additional uncertainties.\u003cbr\u003e\u003cbr\u003e\u003csup\u003e[2]\u003c\/sup\u003e Three thermal cycles from min to max temp, includes hysteresis, 99.9 % confidence (k=3)\u003cbr\u003e\u003cbr\u003e\u003csup\u003e[3]\u003c\/sup\u003eAfter 100 hours at max temp, 99.9 % confidence (k=3)\u003cbr\u003e\u003cbr\u003e\u003csup\u003e[4]\u003c\/sup\u003e Temperatures outside this range will cause irreparable damage. For best performance, transition junction should not be too hot to touch.\u003cbr\u003e\u003cbr\u003e\u003csup\u003e[5]\u003c\/sup\u003e Per ASTM E 644\u003c\/td\u003e\n\u003ctd\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCalibration Uncertainty for accredited† calibration\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eExpanded Uncertainty (k=2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e–197 °C\u003c\/td\u003e\n\u003ctd\u003e0.025 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e–80 °C\u003c\/td\u003e\n\u003ctd\u003e0.025 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e–38 °C\u003c\/td\u003e\n\u003ctd\u003e0.025 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.01 °C\u003c\/td\u003e\n\u003ctd\u003e0.025 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e156 °C\u003c\/td\u003e\n\u003ctd\u003e0.030 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e231 °C\u003c\/td\u003e\n\u003ctd\u003e0.030 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e419 °C\u003c\/td\u003e\n\u003ctd\u003e0.035 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e660 °C\u003c\/td\u003e\n\u003ctd\u003e0.050 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\n\u003cbr\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Calibration uncertainties depend on the uncertainties of the lab performing the calibration. Subsequent calibrations of this probe performed with different processes, at different facilities, or with changed uncertainty statements may state different uncertainties. †Lab code 200348-0\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"models-label\" class=\"tab-pane\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"5608-9-X","offer_id":54038944153894,"sku":"5608-9-X","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"5608-12-X","offer_id":54038944252198,"sku":"5608-12-X","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"5609-12-X","offer_id":54038944284966,"sku":"5609-12-X","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"5609-20-X","offer_id":54038944317734,"sku":"5609-20-X","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"5609-300-X","offer_id":54038944350502,"sku":"5609-300-X","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"5609-400-X","offer_id":54038944383270,"sku":"5609-400-X","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"5609-500-X","offer_id":54038944416038,"sku":"5609-500-X","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"5609-9BND-X","offer_id":54038944448806,"sku":"5609-9BND-X","price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/e11fa24c-e2a1-4927-aa21-b2a40168c2f7_original__size.jpg?v=1791380978","url":"https:\/\/nplab.shop\/products\/5608-5609-secondary-reference-prt","provider":"NP LAB","version":"1.0","type":"link"}