{"product_id":"5606-full-immersion-prt","title":"5606 Full Immersion PRT","description":"\u003cp\u003eThe Fluke Calibration 5606 immersion PRT probe offers excellent accuracy and stability for temperature measurement from -200°C to 160°C.\u003c\/p\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003ch3\u003e\u003cem\u003eUltra-Compact, Reliable, and Designed for Complete Immersion\u003c\/em\u003e\u003c\/h3\u003e\u003ch3\u003eTotal Flexibility for Extreme Environments\u003c\/h3\u003e\u003cp\u003eThe Fluke 5606 Full Immersion Platinum Resistance Thermometer (PRT) offers an unmatched solution for applications where full immersion of the probe—including transition junction and lead wires—is required. With a compact length of just two inches (50 mm) and a sheath diameter of only 1\/8 inch (3.1 mm), the 5606 delivers accuracy and durability in the tightest spaces.\u003c\/p\u003e\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTruly Full Immersion\u003c\/strong\u003e – No need to calculate minimum immersion depth. Simply immerse the entire probe, transition junction, and lead wires over the entire operating range—from –200 °C to 160 °C—in either non-corrosive liquids or dry mediums.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy in a Compact Size\u003c\/strong\u003e – Achieve calibration accuracies as good as ±0.05 °C, thanks to the specially constructed 100 Ω precision sensing element (alpha = 0.00385) that also blocks moisture ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior Moisture Protection\u003c\/strong\u003e – Single-conductor enameled copper lead wires prevent moisture from wicking into the sensing element, offering better protection than traditional stranded leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible and Easy Installation\u003c\/strong\u003e – Lead wires measure no greater than 0.2 mm in diameter, making it simple to route through tight spaces—such as a freezer door—without energy loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProven Durability\u003c\/strong\u003e – The 5606 has demonstrated excellent performance in heat transfer fluids like silicone oil, mineral oil, ethanol, and even liquid nitrogen, with no loss of integrity in the transition junction or lead wire insulation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eEngineered for Demanding Applications\u003c\/h3\u003e\u003cp\u003eThe 5606 Full Immersion PRT is specifically designed to thrive in extreme environments. Both the transition junction and lead wires are built to endure temperatures covering the full probe range, ensuring complete reliability in challenging conditions.\u003c\/p\u003e\u003cp\u003e“\u003cem\u003eImmersion\u003c\/em\u003e” means exposure to extreme temperatures—not just being submerged in a liquid—making the 5606 ideal for a wide variety of rigorous uses.\u003c\/p\u003e\u003cdiv\u003eModels\u003cul\u003e\u003cli\u003e5606-50-X\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e“X” in a model number denotes the probe termination (e.g. A = INFO-CON for 914X, B = bare wire, D = 5-pin DIN, G = gold pins, J = banana plugs, L = mini spade lugs, M = mini banana plugs, P = INFO-CON for 1523\/1524, S = spade lugs). Please specify when enquiring.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications: 5606 Full Immersion PRT\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-200°C to 160°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal resistance at 0.01°C\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e100 Ω ±0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00385 Ω\/Ω\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.04°C at 0.01°C\u003cbr\u003e±0.06°C at 160°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-term repeatability\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.03°C at 0.01°C\u003cbr\u003e±0.04°C at 160°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrift\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.03°C at 0.01°C\u003cbr\u003e±0.04°C at 160°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHysteresis\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.015°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath length\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 mm ±5 mm\u003cbr\u003e(2 in ±0.2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath diameter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.1 mm ±0.1 mm (1\/8 in ±0.004 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath material\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e316 SST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransition junction temperature range\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-200°C to 160°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransition junction dimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNo transition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor length\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30 mm ±3mm (1.2 in ±0.1 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor location\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 mm ±1 mm from tip (1.2 in ±0.04 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum insulation resistance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20 MΩ at 23°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum immersion length\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull immersion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum immersion depth in liquid medium\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull immersion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum immersion depth in dry Medium\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull immersion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12 seconds typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf heating (in 0°C bath)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.003°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead-wire cable type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEnameled copper wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead-wire length\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.4 meters (8 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead-wire temperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e160°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCalibration not included. NVLAP accredited calibration available. See ordering information.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e1. Includes calibration and 100 hr drift (k = 2).\u003cbr\u003e2. Three thermal cycles from min to max temp, includes hysteresis, 95% confidence (k = 2).\u003cbr\u003e3. After 100 hours at max temp, 95% confidence (k = 2).\u003cbr\u003e4. Temperatures outside this range will cause irreparable damage.\u003cbr\u003e5. Per ASTM E 644.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eCalibration Uncertainty\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-197°C\u003c\/td\u003e\n\u003ctd\u003e1924 Calibration Uncertainty\u003csup\u003e6\u003c\/sup\u003e 0.03°C\u003cbr\u003eTolerance w\/out Calibration\u003csup\u003e7\u003c\/sup\u003e 0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-38°C\u003c\/td\u003e\n\u003ctd\u003e1924 Calibration Uncertainty\u003csup\u003e6\u003c\/sup\u003e 0.03°C\u003cbr\u003eTolerance w\/out Calibration\u003csup\u003e7\u003c\/sup\u003e 0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003ctd\u003e1924 Calibration Uncertainty\u003csup\u003e6\u003c\/sup\u003e 0.03°C\u003cbr\u003eTolerance w\/out Calibration\u003csup\u003e7\u003c\/sup\u003e 0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100°C\u003c\/td\u003e\n\u003ctd\u003e1924 Calibration Uncertainty\u003csup\u003e6\u003c\/sup\u003e 0.045°C\u003cbr\u003eTolerance w\/out Calibration\u003csup\u003e7\u003c\/sup\u003e 0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e157°C\u003c\/td\u003e\n\u003ctd\u003e1924 Calibration Uncertainty\u003csup\u003e6\u003c\/sup\u003e 0.05°C\u003cbr\u003eTolerance w\/out Calibration\u003csup\u003e7\u003c\/sup\u003e 0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e6. Lab code 200348-0\u003cbr\u003e7. Each PRT includes a certificate with a measured R0 value.\u003cbr\u003eAn uncalibrated 5606 meets ASTM E 1137 Grade A Classification of Tolerances.\u003cbr\u003eUse the coefficients below to achieve the tolerances listed in the “No Calibration” column or calculate the Grade A tolerance using the following formula:\u003cbr\u003eGrade A = ±[0.13 + 0.0017|t|]°C\u003cbr\u003ewhere: |t| = value of temperature (°C) without regard to sign. See ASTM E 1137.\u003cbr\u003eR0: Enter the R0 value provided\u003cbr\u003eA: 3.9083 x 10\u003csup\u003e–3\u003c\/sup\u003e\u003cbr\u003eB: –5.775 x 10\u003csup\u003e–7\u003c\/sup\u003e\u003cbr\u003eC: –4.183 x 10\u003csup\u003e–12\u003c\/sup\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"models-label\" class=\"tab-pane\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"5606-50-X","offer_id":54038943990054,"sku":"5606-50-X","price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/27c072a8-8635-4ea7-a6b6-b29f011f17b2_original__size.jpg?v=1791380958","url":"https:\/\/nplab.shop\/products\/5606-full-immersion-prt","provider":"NP LAB","version":"1.0","type":"link"}