{"product_id":"1524-handheld-thermometer-readout","title":"1524 Handheld Reference Thermometer Readout","description":"\u003cp\u003eThe 1524 Reference Thermometers from Fluke’s Hart Scientific Division measure, graph, and record PRTs, thermocouples, and thermistors.\u003c\/p\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eMake accurate, consistent measurements… anywhere.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eYou need accuracy for compliance, product yields, energy savings, and consistent results. The 1524 uses current reversal, a technique used in high-end instruments that eliminates thermal EMFs, for precision temperature measurements. Specifications are guaranteed from -10 °C to 60 °C ambient. Special precision resistors and a highly stable reference voltage source keep 1524 accuracy virtually insensitive to environmental temperature.\u003c\/p\u003e\u003cp\u003eLike all Fluke handheld tools, the 1524 Reference Thermometers endure rigorous testing in temperature extremes and under harsh conditions of vibration, so you can take them anywhere you need to go.\u003c\/p\u003e\u003cp\u003eAn optional magnetic hanger allows you to hang the thermometer for easy viewing while freeing your hands to focus on the job.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINFO-CON connectors ensure correct temperature conversion\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eInside the INFO-CON, a memory chip keeps calibration information for the attached probe. Simply plugging in the probe uploads the information to the readout, ensuring the correct temperature conversion for accurate, hassle-free measurements.\u003c\/p\u003e\u003cp\u003eProbes may be locked by password to specific channels and readouts for security or for system calibration traceability. Plug any thermocouple with mini-thermocouple jacks into an optional universal thermocouple adapter for convenient measurement. Each thermocouple adapter or standard connector supports reference junction compensation (RJC) with its own internal precision thermistor.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMonitor trends in the lab or in the field\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSee trends graphically on the 1524 thermometer’s 128x64-backlit LCD display. You can change the graph’s resolution at the touch of a button. Now it’s easy to see when the temperature is stable, without statistics or long delays, or monitor processes over time to verify correct operation.\u003c\/p\u003e\u003cp\u003eDocument on demand up to 25 readings and associated statistics for easy retrieval. You can view the data through the display or by uploading it to a PC via RS-232 connection and 9940 software, included free. To monitor and log more data over time, use a PC and optional LogWare II software.\u003c\/p\u003e\u003cp\u003eRS-232-to-USB adapters are available for those who prefer USB connectors. Battery power lasts at least 20 hours on three AA batteries, or use the dc power adapter for extended periods of measurement. Power saving features can be enabled or disabled for longer battery life or greater convenience.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe new 1524 Reference Thermometers help you do twice the work in half the time. Two channels and three sensor types and high-speed measurement make you more productive and make model 1524 the one reference thermometer you need to own. It has all the features of the 1523, and it’s a data logger too. A real-time clock and memory for 15,000 time and date stamped measurements mean everything you are going to need is in this package. Log up to three times per second, or once every hour or other options in between. Download the data to a PC for analysis when you need it.\u003c\/p\u003e\u003cp\u003eCalibration, loop checking, plant startup, troubleshooting, maintenance, and repair are some of the varied duties that need a 1524 thermometer. Use it for a handy temperature reference in baths, dry-block calibrators, thermowells, clean rooms, engines, heat exchangers, furnaces, freezers, or anything else that must be calibrated, checked, or maintained.\u003c\/p\u003e\u003cdiv\u003eModels\u003cul\u003e\n\u003cli\u003e1524\u003c\/li\u003e\n\u003cli\u003e1524-P2\u003c\/li\u003e\n\u003cli\u003e1524-P3\u003c\/li\u003e\n\u003cli\u003e1524-P4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke Calibration 1524 Handheld Thermometer Readout\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging\u003c\/td\u003e\n\u003ctd\u003e15,000 time and date stamped; 25 readings with statistics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample interval\u003cbr\u003e(normal)\u003c\/td\u003e\n\u003ctd\u003e1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample interval (fast mode)\u003c\/td\u003e\n\u003ctd\u003e0.3 seconds (see technical manual for details)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor types\u003c\/td\u003e\n\u003ctd\u003ePRTs, RTDs, thermistors, and thermocouples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple types\u003c\/td\u003e\n\u003ctd\u003eC, E, J, K, L, M, N, T, U, B, R, S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 60°C (Best accuracy 13°C to 33°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower requirements\u003c\/td\u003e\n\u003ctd\u003e3 AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e96 x 200 x 47 mm\u003cbr\u003e(3.75 x 7.9 x 1.86 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.65 kg (1.4 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental conditions for best accuracy\u003c\/td\u003e\n\u003ctd\u003e13°C to 33°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMillivolt range and accuracy\u003c\/td\u003e\n\u003ctd\u003e–10 mV to 75 mV ±(0.005% + 5 μV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance range and accuracy\u003c\/td\u003e\n\u003ctd\u003e0 Ω to 400 Ω ±(0.004% + 0.002 Ω)\u003cbr\u003e200 Ω to 50 kΩ ±(0.01% + 0.5 Ω)\u003cbr\u003e50 kΩ to 500 kΩ ± (0.03%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient, voltage (–10°C to 13°C, +33°C to 60°C)\u003c\/td\u003e\n\u003ctd\u003e±(0.001%\/°C + 1 μV\/°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient, resistance (–10°C to 13°C, +33°C to 60°C)\u003c\/td\u003e\n\u003ctd\u003e0.0008%\/°C + 0.0004 Ω (0 Ω to 400 Ω)\u003cbr\u003e0.002%\/°C + 0.1 Ω (0 Ω to 50 kΩ)\u003cbr\u003e0.06%\/°C + 0.1 Ω (50 kΩ to 500 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation current, resistance\u003c\/td\u003e\n\u003ctd\u003e1 mA (0 Ω to 400 Ω)\u003cbr\u003e10 μA (0 Ω to 50 kΩ)\u003cbr\u003e2 µA (50 kΩ to 500 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eThermocouple Equivalent Temperature Accuracies (Readout Only)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType B\u003c\/td\u003e\n\u003ctd\u003e±0.85°C from 600°C to 800°C\u003cbr\u003e±0.68°C from 800°C to 1000°C\u003cbr\u003e±0.57°C from 1000°C to 1800°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003ctd\u003e±0.32°C from 100ºC to 550°C\u003cbr\u003e±0.71°C from 550°C to 2300°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType E\u003c\/td\u003e\n\u003ctd\u003e±0.52°C from -200°C to 0°C\u003cbr\u003e±0.22°C from 0°C to 950°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType J\u003c\/td\u003e\n\u003ctd\u003e±0.52°C from -200°C to 0°C\u003cbr\u003e±0.23°C from 0°C to 1200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003ctd\u003e±0.61°C from -200°C to 0°C\u003cbr\u003e±0.24°C from 0°C to 1370°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType L\u003c\/td\u003e\n\u003ctd\u003e±0.36°C from -200°C to 0°C\u003cbr\u003e±0.23°C from 0°C to 1370°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType M\u003c\/td\u003e\n\u003ctd\u003e±0.26°C from -20°C to 0°C\u003cbr\u003e±0.25°C from 0°C to 400°C\u003cbr\u003e±0.22°C from 400°C to 1400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType N\u003c\/td\u003e\n\u003ctd\u003e±0.72°C from -200°C to 0°C\u003cbr\u003e±0.28°C from 0°C to 1300°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType R\u003c\/td\u003e\n\u003ctd\u003e±1.09°C from -20°C to 0°C\u003cbr\u003e±0.97°C from 0°C to 500°C\u003cbr\u003e±0.49°C from 500°C to 1750°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType S\u003c\/td\u003e\n\u003ctd\u003e±1.05°C from -20°C to 0°C\u003cbr\u003e±0.95°C from 0°C to 500°C\u003cbr\u003e±0.56°C from 500°C to 1750°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType T\u003c\/td\u003e\n\u003ctd\u003e±0.60°C from -200°C to 0°C\u003cbr\u003e±0.25°C from 0°C to 400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType U\u003c\/td\u003e\n\u003ctd\u003e±0.54°C from -200°C to 0°C\u003cbr\u003e±0.24°C from 0°C to 400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eAccuracies are based on internal reference junction compensation. Refer to technical manual for equivalent accuracies with an external reference junction.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e1524 Accuracies with Selected Probes (±°C)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-200°C\u003c\/td\u003e\n\u003ctd\u003e5616-12: 0.014\u003cbr\u003e5615-6: 0.025\u003cbr\u003e5627A-12: 0.027\u003cbr\u003e5610-9: n\/a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003ctd\u003e5616-12: 0.021\u003cbr\u003e5615-6: 0.021\u003cbr\u003e5627A-12: 0.049\u003cbr\u003e5610-9: 0.009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100°C\u003c\/td\u003e\n\u003ctd\u003e5616-12: 0.027\u003cbr\u003e5615-6: 0.028\u003cbr\u003e5627A-12: 0.065\u003cbr\u003e5610-9: 0.009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e300°C\u003c\/td\u003e\n\u003ctd\u003e5616-12: 0.040\u003cbr\u003e5615-6: 0.043\u003cbr\u003e5627A-12: 0.103\u003cbr\u003e5610-9: n\/a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e420°C\u003c\/td\u003e\n\u003ctd\u003e5616-12: 0.050\u003cbr\u003e5615-6: n\/a\u003cbr\u003e5627A-12: 0.130\u003cbr\u003e5610-9: n\/a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003ePRT Equivalent Temperature Accuracy (Readout only)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e–100°C\u003c\/td\u003e\n\u003ctd\u003e±0.011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003ctd\u003e±0.015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100°C\u003c\/td\u003e\n\u003ctd\u003e±0.019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200°C\u003c\/td\u003e\n\u003ctd\u003e±0.023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400°C\u003c\/td\u003e\n\u003ctd\u003e±0.031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600°C\u003c\/td\u003e\n\u003ctd\u003e±0.039\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eThermistor Equivalent Temperature Accuracy (Readout Only)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003ctd\u003e±0.002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25°C\u003c\/td\u003e\n\u003ctd\u003e±0.003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50°C\u003c\/td\u003e\n\u003ctd\u003e±0.006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75°C\u003c\/td\u003e\n\u003ctd\u003e±0.014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100°C\u003c\/td\u003e\n\u003ctd\u003e±0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"models-label\" class=\"tab-pane\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"1524","offer_id":54038941139238,"sku":"1524","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"1524-P2","offer_id":54038941204774,"sku":"1524-P2","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"1524-P3","offer_id":54038941237542,"sku":"1524-P3","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"1524-P4","offer_id":54038941270310,"sku":"1524-P4","price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/b5b65acb-e724-49aa-b81b-b108002c72fc_original__size.jpg?v=1791380832","url":"https:\/\/nplab.shop\/products\/1524-handheld-thermometer-readout","provider":"NP LAB","version":"1.0","type":"link"}