{"title":"Com-power","description":"","products":[{"product_id":"cdn-m","title":"CDN-M 150kHz-230MHz","description":"\u003cp\u003e\u003cstrong\u003eCDN-M Series — unscreened powerline Coupling Decoupling Networks, 150 kHz–230 MHz\u003c\/strong\u003e — Com-Power M-series CDNs for IEC 61000-4-6 conducted immunity on power conductors. Choose Model by line count and continuous current rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModels from 1-line 25 A to 5-line 25 A\u003c\/strong\u003e — single-, two-, three-, four-, and five-line configurations covering PE-only through full 3L+N+PE European industrial mains.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e150 Ω common-mode impedance, BNC RF port\u003c\/strong\u003e — standard IEC 61000-4-6 coupling profile for accurate test-level setting at 1, 3, and 10 V\u003csub\u003erms\u003c\/sub\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNIST-traceable individual calibration with three-year warranty\u003c\/strong\u003e — ISO\/IEC 17025 accredited calibration optional; ADA calibration adapters available separately; integrates into Com-Power Conducted Immunity Test Systems.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"CDN-M125E - 1-line 25A","offer_id":53344280052006,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true},{"title":"CDN-M1100 - 1-line 100A","offer_id":53896841691430,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true},{"title":"CDN-M225E - 2-line 25A","offer_id":53896841724198,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true},{"title":"CDN-M250E - 2-line 50A","offer_id":53896841756966,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true},{"title":"CDN-M2100 - 2-line 100A","offer_id":53896841789734,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true},{"title":"CDN-M325E - 3-line 25A","offer_id":53896841822502,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true},{"title":"CDN-M350E - 3-line 50A","offer_id":53896841855270,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true},{"title":"CDN-M425E - 4-line 25A","offer_id":53896841888038,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true},{"title":"CDN-M450E - 4-line 50A","offer_id":53896841920806,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true},{"title":"CDN-M525E - 5-line 25A","offer_id":53896841953574,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/CDN-M125E.jpg?v=1781490992"},{"product_id":"isn-cdn-c","title":"ISN\/CDN-C 150kHz-230MHz","description":"\u003cp\u003e\u003cstrong\u003eISN\/CDN-C Series — coaxial Coupling Decoupling Networks \/ Impedance Stabilization Networks\u003c\/strong\u003e — Com-Power dual-function units for 50 Ω and 75 Ω coax. Use as ISN for conducted emissions (150 kHz–30 MHz) or as CDN for IEC 61000-4-6 conducted immunity (150 kHz–230 MHz).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose Model by characteristic impedance\u003c\/strong\u003e — C50E (50 Ω) or C75E (75 Ω) BNC EUT\/AE ports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e150 Ω common-mode termination per CISPR 22\/32\u003c\/strong\u003e — stable, repeatable disturbance voltage at the measurement port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndividually calibrated; unpainted bottom bonds to reference ground plane\u003c\/strong\u003e — three-year warranty; pairs with SPA-900TG series spectrum analyzer \/ EMI receiver.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"ISN\/CDN-C50E - 50Ω","offer_id":53344365478182,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true},{"title":"ISN\/CDN-C75E - 75Ω","offer_id":53896862695718,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/ISN_CDN-C50E.jpg?v=1781493404"},{"product_id":"isn-cdn-t8se","title":"ISN\/CDN-T8SE","description":"\u003cp\u003e\u003cstrong\u003eImpedance Stabilization Network (ISN) for shielded telecom ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— measures common-mode conducted emissions on screened (shielded) lines with up to four balanced pairs per EN 55022\/32 (CISPR 22\/32) and CISPR 16-1-2. ISN role applied 150 kHz–30 MHz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e150 Ω common-mode termination per CISPR 22\/32\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— standard-defined impedance on the screened pairs so disturbance voltage at the measurement port is stable and repeatable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShielded RJ-45 receptacles on EUT and AE ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— direct mate with shielded Cat-5e\/Cat-6\/Cat-6A patch cords; no adapters required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShielded Ethernet ports on ITE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— PoE switches, NICs, routers, network appliances, and servers with shielded RJ-45 jacks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Ethernet \/ Profinet \/ EtherCAT shielded drops\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— field switches, drives, and I\/O modules using shielded balanced pairs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e50 Ω BNC measurement port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon top of housing — direct mate to spectrum analyzer \/ EMI receiver for the disturbance voltage scan.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso usable as a CDN for IEC\/EN 61000-4-6 conducted immunity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— secondary capability over the full 150 kHz–230 MHz band when needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndividually calibrated; compact and light at 2 lbs (0.9 kg)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— outer surface designed for grounding to the reference plane; pairs with the SPA-900TG series spectrum analyzer \/ EMI receiver.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"ISN\/CDN-T8SE","offer_id":53344367083814,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/CDN-T8SE.jpg?v=1781493630"},{"product_id":"isn-t","title":"ISN-T","description":"\u003cp\u003e\u003cstrong\u003eISN-T Series — unshielded telecom Impedance Stabilization Networks, 150 kHz–30 MHz\u003c\/strong\u003e — Com-Power emissions ISNs for measuring common-mode disturbance voltage on unshielded balanced telecom pairs per CISPR 22\/32.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose Model by pair count\u003c\/strong\u003e — ISN-T2 (1 unshielded balanced pair) or ISN-T8 (up to 4 unshielded balanced pairs).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e150 Ω common-mode impedance per CISPR 22\u003c\/strong\u003e — defined termination for stable, repeatable disturbance voltage at the measurement port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndividually calibrated; pairs with SPA-900TG series spectrum analyzer \/ EMI receiver\u003c\/strong\u003e for conducted telecom emissions scans.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"ISN-T2","offer_id":53344368361766,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true},{"title":"ISN-T8","offer_id":53896876491046,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/ISN-T2.png?v=1781493758"},{"product_id":"cg-515","title":"CG-515","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCG-515\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a battery-operated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eradiated comb generator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEMC reference signal source\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecovering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 MHz to 1.5 GHz\u003c\/strong\u003e, recognized as an artifact for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAutomotive EMC Laboratory Recognition Program (AEMCLRP)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser-selectable 1 MHz or 5 MHz step size\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— choose 1 MHz for high-resolution baseline data or 5 MHz for faster sweeps with cleaner spectral lines on the EMI receiver display.\u003c\/p\u003e\n\u003cp\u003eCompact\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecubic chassis\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— just 2.9″ × 3.1″ × 3.1″ (7.4 × 7.9 × 7.9 cm) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5 lbs (0.2 kg)\u003c\/strong\u003e; the smallest, lightest comb generator in the lineup with two interchangeable monopoles (3-inch and 12-inch).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDaily site verification on OATS, SAC, and FAC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— quick pre-test checks at a few reference frequencies catch broken cables, blown preamps, and oxidized connectors that would otherwise produce months of invalid compliance data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomotive EMC pre-compliance verification (CISPR 25)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the AEMCLRP-recognized artifact for inter-laboratory comparison and ongoing site validation in vehicle component test labs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable, attenuator, and filter insertion-loss measurements\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the broadband output also serves as a stable reference source for chamber-to-chamber comparisons and RF accessory characterization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e18+ hours per charge\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einternal NiMH battery eliminates external power cabling that could disturb the radiated pattern; automatic low-battery shut-off protects baseline integrity.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 ppm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrequency stability,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±0.1 dB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eamplitude stability.\u003c\/p\u003e\n\u003cp\u003eIndividually\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNIST-traceable calibrated\u003c\/strong\u003e; ISO 17025 calibration available on request.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree-year warranty.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344373670182,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/CG-515.jpg?v=1781494145"},{"product_id":"cgc-105","title":"CGC-105","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCGC-105\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a battery-powered\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econducted comb generator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLISN reference signal source\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecovering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10 kHz to 115 MHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the lowest-frequency conducted reference in the Com-Power lineup, ideal for CISPR 16 and CISPR 32 \/ EN 55032 conducted emissions verification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser-selectable 10 kHz or 50 kHz step size\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— choose 10 kHz for high-resolution baseline data near the lower band edge or 50 kHz for faster sweeps with cleaner spectral lines on the EMI receiver.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh output impedance design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows safe use whether the LISN is powered, unpowered, or connected to AC mains — no need to disconnect the EUT power source between verification checks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInterchangeable output adapter system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(CGC-P25A, CGC-P50A, CGC-P100A) plus optional CGC-105P-ADA-CAL and CGC-105P-ADA-USP adapters connect directly to most LISN EUT power port pin configurations and AC receptacles worldwide.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerifies the entire conducted measurement chain\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— LISN, RF cables, transient limiter, and EMI receiver — in minutes between formal calibrations; output levels are close to or above CISPR disturbance limits for clear receiver visibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial, scientific, and medical (ISM) equipment verification under CISPR 11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the 10 kHz starting frequency covers Group 1 ISM applications below the standard 150 kHz band edge.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongest battery life in the lineup — 23+ hours per charge\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon internal 6 V \/ 1 Ah NiMH; supports multiple full days of testing without recharging.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 ppm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrequency stability,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±0.1 dB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eamplitude stability.\u003c\/p\u003e\n\u003cp\u003eCompact 6.5 × 2.3 × 2.4″ (165 × 58 × 61 mm), 0.5 lbs (0.22 kg).\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNIST-traceable calibration\u003c\/strong\u003e; ISO 17025 available on request.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree-year warranty.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344383140134,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/CGC-105.png?v=1781494287"},{"product_id":"cgc-255e","title":"CGC-255E","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCGC-255E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a battery-powered\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econducted comb generator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLISN reference signal source\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecovering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 kHz to 115 MHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— ideal for CISPR 22 \/ CISPR 32 \/ EN 55032 Class A and Class B conducted emissions verification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser-selectable 50 kHz or 250 kHz step size\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— choose 50 kHz for higher resolution near the band edge or 250 kHz for sparser, faster sweeps with easier harmonic identification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA 15-P plug connects directly to the LISN EUT power port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— standard three-blade interface; international socket types accommodated via adapters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSimulates an EUT generating conducted EMI noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— replicates real-device operating conditions for verification of LISN impedance, transient limiter, and EMI receiver under realistic loading.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuick LISN verification before high-stakes testing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— plug into each LISN EUT port and confirm baseline within 1 dB at multiple frequencies in minutes; catches LISN drift, cable failures, and connector corrosion immediately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduction component evaluation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— broadband output also useful for spot-checking cable shields, EMI filters, and ferrite suppressors without expensive VNA equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e18+ hours battery operation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon internal 6 V \/ 1 Ah NiMH; battery elimination of external power leads prevents noise coupling into the conducted measurement.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 ppm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrequency stability,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±0.1 dB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eamplitude stability.\u003c\/p\u003e\n\u003cp\u003eCompact 5 × 2.2 × 2.2″ (13.2 × 5.9 × 5.9 cm), 1 lb (0.45 kg).\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNIST-traceable calibration\u003c\/strong\u003e; ISO 17025 available on request.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree-year warranty.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344386122022,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/CGC-255E.jpg?v=1781494445"},{"product_id":"cgc-510e","title":"CGC-510E","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCGC-510E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a battery-powered\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econducted comb generator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLISN reference signal source\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecovering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100 kHz to 115 MHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— ideal for FCC Part 15 Subpart B and EN 55032 \/ CISPR 32 conducted emissions test site verification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser-selectable 100 kHz or 500 kHz step size\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— choose 100 kHz for higher-resolution baseline data near the lower band edge or 500 kHz for fast sweeps with cleaner spectral lines on the EMI receiver.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh impedance to external line voltage (AC or DC up to 230 V)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— allows safe use while the LISN is connected to an external power source, no need to disconnect mains between verification checks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA 15-P plug connects directly to the LISN EUT power port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— standard three-blade interface for North American LISNs; adapters accommodate international socket types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSimulates an EUT generating conducted EMI noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— replicates real-device operating conditions for verification of LISN impedance, RF cabling, transient limiter, and EMI receiver under realistic loading.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDaily verification of CISPR conducted emissions test setups\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— quick checks at 150 kHz, 500 kHz, 5 MHz, and 30 MHz catch LISN drift, oxidized connectors, and spectrum analyzer attenuator failures before they corrupt compliance data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e18+ hours battery operation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon internal 6 V \/ 1 Ah NiMH; battery elimination of external power leads prevents noise coupling into the conducted measurement.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 ppm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrequency stability,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±0.1 dB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eamplitude stability.\u003c\/p\u003e\n\u003cp\u003eCompact 5 × 2.2 × 2.2″ (13.2 × 5.9 × 5.9 cm), 1 lb (0.45 kg).\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNIST-traceable calibration\u003c\/strong\u003e; ISO 17025 available on request.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree-year warranty.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344386416934,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/CGC-510E.jpg?v=1781494570"},{"product_id":"cgo-501","title":"CGO-501","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCGO-501\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a battery-powered\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eradiated comb generator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebroadband EMC signal source\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecovering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 MHz to 1.5 GHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fixed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 MHz steps\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the highest-resolution radiated reference in this band.\u003c\/p\u003e\n\u003cp\u003ePen-style\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecylindrical chassis\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— 7″ × 1.2″ (17.8 × 3 cm), 1.5 lbs (0.7 kg) — with two interchangeable monopoles (5-inch and 12-inch) that optimize radiation across the lower and upper bands.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFCC Part 15 \/ CISPR 32 \/ EN 55032 radiated emissions verification\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— covers the full commercial radiated test band; place on the turntable to validate the entire measurement chain in minutes before each compliance test.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOATS, semi-anechoic chamber (SAC), and fully-anechoic chamber (FAC) site checks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— quick reference measurements at strategic frequencies catch failing preamps, broken cables, and bad connectors between formal NSA calibrations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDense 1 MHz step resolution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ereveals narrowband anomalies that wider-step generators miss — ideal for industrial, scientific, and medical (ISM) equipment verification under\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCISPR 11\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsertion loss measurements\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon cables, attenuators, filters, and connectors; also useful for inter-site comparisons and chamber correlation studies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e18+ hours battery operation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon internal 6 V \/ 1 Ah NiMH; automatic low-battery shut-off protects data integrity.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 ppm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrequency stability,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±0.1 dB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eamplitude stability,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u0026lt;1 dB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edrift over 12 months.\u003c\/p\u003e\n\u003cp\u003eCustom carrying case and charger included;\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNIST-traceable calibration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith certificate. ISO 17025 available on request.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree-year warranty.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344387268902,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/CGO-501.jpg?v=1781494708"},{"product_id":"cgo-505","title":"CGO-505","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCGO-505\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a battery-powered\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eradiated comb generator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebroadband EMC signal source\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecovering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5 MHz to 1.5 GHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fixed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5 MHz steps\u003c\/strong\u003e, the most popular general-purpose radiated reference in this band.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy 5 MHz steps?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLower energy density per MHz makes individual harmonics stand out cleanly on EMI receivers, the output remains usable to the full 1.5 GHz, and faster sweeps speed up daily site checks.\u003c\/p\u003e\n\u003cp\u003ePen-style\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecylindrical chassis\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— 7″ × 1.2″ (17.8 × 3 cm), 1.5 lbs (0.7 kg) — with two interchangeable monopoles (5-inch and 12-inch) for optimal radiation across the band.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFCC Part 15 \/ CISPR 32 \/ EN 55032 radiated emissions verification\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the workhorse comb generator for daily site validation in commercial EMC compliance laboratories.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOATS, SAC, and FAC site verification\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— reference measurements at 30 MHz, 230 MHz, and 1 GHz catch failing preamps, broken cables, and oxidized connectors immediately, before months of invalid data accumulate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsertion loss measurements\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon cables, attenuators, filters, and connectors; also serves as a stable reference for chamber-to-chamber comparisons and shielding effectiveness tests.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e18+ hours battery operation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon internal 6 V \/ 1 Ah NiMH; automatic low-battery shut-off protects baseline integrity.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 ppm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrequency stability,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±0.1 dB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eamplitude stability.\u003c\/p\u003e\n\u003cp\u003eIndividually\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNIST-traceable calibrated\u003c\/strong\u003e; ISO 17025 available on request.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree-year warranty.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344388710694,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/CGO-505.jpg?v=1781494813"},{"product_id":"cgo-51000","title":"CGO-51000","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCGO-51000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a battery-powered\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emillimeter-wave comb generator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebroadband EMC reference signal source\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecovering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 GHz to 40 GHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 GHz steps\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the highest-frequency comb generator in the Com-Power lineup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5G FR2 mmWave site verification\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— covers the 24, 28, 37, and 39 GHz 5G bands plus automotive radar (24, 38, 76–81 GHz partial coverage), satellite communications, and CISPR 32 \/ FCC Part 15 emissions through 40 GHz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntegral stub antenna with protective cover\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon a circular chassis ground plane produces a uniform omnidirectional radiated reference signal; supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eboth vertical and horizontal polarization\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto match receive antenna orientation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCatches mmWave faults missed by annual NSA calibration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— at millimeter-wave frequencies, even tiny connector contamination or wear causes severe degradation; daily checks detect cable, antenna, or preamp faults before invalid data accumulates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1 GHz step provides 40 well-separated reference markers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross the microwave \/ mmWave spectrum, easy to identify on spectrum analyzers without harmonic crowding.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOATS, SAC, and FAC verification at mmWave frequencies\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the only practical reference source for daily site checks at 26 GHz, 28 GHz, and beyond, where traditional calibration methods are slow and expensive.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e25 ppm frequency stability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures comb teeth stay aligned to receiver bin centers across the full 40 GHz span over weeks of repeated daily checks.\u003c\/p\u003e\n\u003cp\u003eCompact 7″ × 1″ (17.8 × 2.5 cm) circular chassis, 2.5 lbs (1.1 kg); 18+ hours battery life on 6 V NiMH.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNIST-traceable calibration\u003c\/strong\u003e; ISO 17025 available.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree-year warranty.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344389267750,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/CGO-51000.jpg?v=1781494916"},{"product_id":"cgo-5100b","title":"CGO-5100B","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCGO-5100B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a battery-powered\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emicrowave comb generator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebroadband EMC reference signal source\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecovering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 GHz to 18 GHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fixed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100 MHz steps\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the most economical microwave radiated reference for EMC test sites.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5 ppm frequency stability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— tighter tolerance than lower-band models, critical at microwave frequencies where receiver resolution bandwidths are narrower.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in stub antenna\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon a circular chassis ground plane produces a uniform omnidirectional radiated reference signal in the horizontal plane — no antenna swap-outs required across the band.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMicrowave radiated emissions verification\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor FCC Part 15, CISPR 32 \/ EN 55032, MIL-STD-461 RE102 upper band, and RTCA DO-160 radiated; ideal for verifying microwave horn antennas, preamplifiers, and high-frequency cabling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5G sub-18 GHz site verification\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— covers 5G FR2 lower bands (24 GHz approach) and most automotive radar pre-compliance testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDetects connector and cable issues missed by annual NSA calibration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— at microwave frequencies, even slightly oxidized or loose connectors cause dB-level errors; daily checks catch degradation immediately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShielding effectiveness measurements\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon enclosures and materials across the microwave band; place inside the enclosure and measure leakage outside with a horn antenna.\u003c\/p\u003e\n\u003cp\u003eCompact 6″ × 1″ (15.24 × 2.54 cm) circular chassis, 1 lb (0.45 kg); ~18 hours per charge on 3.6 V NiMH battery.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNIST-traceable calibration\u003c\/strong\u003e; ISO 17025 available on request.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree-year warranty.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344392020262,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/CGO-5100B.jpg?v=1781495228"},{"product_id":"cgo-515","title":"CGO-515","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCGO-515\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a battery-powered\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eradiated comb generator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebroadband EMC signal source\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecovering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 MHz to 1.5 GHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003euser-selectable 1 MHz or 5 MHz step sizes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the most versatile radiated reference in this band.\u003c\/p\u003e\n\u003cp\u003ePen-style\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecylindrical chassis\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— 7″ × 1.2″ (17.8 × 3 cm), 1.5 lbs (0.7 kg) — with circular base for uniform omnidirectional radiated reference signal in all directions.\u003c\/p\u003e\n\u003cp\u003eTwo interchangeable monopoles (\u003cstrong\u003e5-inch and 12-inch\u003c\/strong\u003e) supplied for optimized radiation across the lower- and higher-frequency portions of the band.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFCC Part 15 \/ CISPR 32 \/ EN 55032 radiated emissions verification\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— ideal daily site reference for commercial EMC compliance laboratories.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOATS, SAC, and FAC site validation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— switch to 1 MHz steps for high-resolution baseline data; switch to 5 MHz steps for fast sweeps and cleaner spectral lines on the receiver.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsertion loss\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emeasurements on cables, attenuators, and filters;\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etest site comparison\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estudies for inter-chamber correlation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e18+ hours battery operation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon internal 6 V \/ 1 Ah NiMH; automatic low-battery shut-off; battery elimination of external cabling prevents radiated pattern disturbance.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 ppm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrequency stability,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±0.1 dB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eamplitude stability.\u003c\/p\u003e\n\u003cp\u003eIndividually\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNIST-traceable calibrated\u003c\/strong\u003e; ISO 17025 available on request.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree-year warranty.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344392118566,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/CGO-515.jpg?v=1781495333"},{"product_id":"cgo-520","title":"CGO-520","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCGO-520\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a battery-powered\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eradiated comb generator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebroadband EMC reference signal source\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecovering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 MHz to 4.5 GHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fixed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 MHz steps\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the highest-frequency comb generator with detachable antennas in the lineup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCircular base for uniform omnidirectional radiation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the chassis acts as a ground plane producing consistent radiated output regardless of orientation on the turntable.\u003c\/p\u003e\n\u003cp\u003eTwo detachable interchangeable monopoles (\u003cstrong\u003e2-inch and 12-inch\u003c\/strong\u003e) supplied for optimized radiation across the lower- and higher-frequency portions of the 4.5 GHz range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5G FR1 sub-6 GHz radiated emissions verification\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— covers the WiFi, Bluetooth, cellular, and FCC Part 15 \/ CISPR 32 microwave bands relevant to wireless device compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomotive EMC under CISPR 25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the extended 4.5 GHz reach covers vehicle wireless module compliance bands for in-vehicle radiated testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOATS, SAC, and FAC site validation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eat frequencies above 1 GHz where traditional comb generators run out of range; quick daily checks catch microwave preamp degradation and high-frequency cable failures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e18+ hours battery operation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon internal 6 V \/ 1 Ah NiMH; battery elimination of external cabling is critical above 1 GHz to prevent radiated pattern disturbance.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 ppm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrequency stability,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±0.1 dB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eamplitude stability.\u003c\/p\u003e\n\u003cp\u003eCompact pen-style chassis 7″ × 1″ (17.8 × 2.5 cm), 1.5 lbs (0.7 kg). Individually\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNIST-traceable calibrated\u003c\/strong\u003e; ISO 17025 available on request.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree-year warranty.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344392872230,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/CGO-520.jpg?v=1781495487"},{"product_id":"li-1100c","title":"LI-1100C","description":"\u003cp\u003e\u003cstrong\u003eHigh-current 100 A single-phase LISN, 150 kHz to 30 MHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the highest current rating in the 1x series and the standard choice for industrial, three-phase commercial, and heavy-duty single-phase products requiring CISPR 16-1-2 \/ ANSI C63.4 conducted emissions testing.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e▸\u003c\/span\u003e\u003cstrong\u003eSeparately housed single-conductor networks with SUPERCON® shrouded sockets\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— one 50 µH air-core network per current-carrying conductor allows flexible installation in single-phase, dual-phase, DC, and three-phase configurations (a second pair extends to Wye \/ Delta three-phase).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAir-core 50 µH inductors, 270 V\u003csub\u003eAC\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\/ 380 V\u003csub\u003eDC\u003c\/sub\u003e, 50 Ω N-type RF port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— CISPR 16-1-2 V-network performance maintained at 100 A continuous; insertion loss below 0.5 dB and isolation above 40 dB across 150 kHz to 30 MHz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial machinery and motor drives drawing up to 100 A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— large variable frequency drives, industrial automation cabinets, machine tools, and CNC equipment requiring CISPR 11 \/ IEC 61000-6-4 industrial emissions qualification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThree-phase commercial equipment via two LI-1100C pairs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— data center UPS systems up to 25 kW, large commercial HVAC and refrigeration plants, three-phase server racks, and other commercial three-phase equipment qualifying for CE and FCC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEV charging stations and high-power power conversion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— AC charging infrastructure on single-phase 240 V circuits up to 100 A, large industrial battery chargers, and grid-tied inverters where the 100 A headroom is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWelding equipment and high-current industrial heating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— arc welders, induction heaters, and resistive heating equipment drawing tens of amps continuous on single-phase mains with FCC Part 18 or CISPR 11 conducted emissions requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNIST-traceable individual calibration with three-year warranty\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— impedance, phase, isolation, and insertion loss data supplied per network with calibration certificate; ISO 17025 accredited calibration available on request; recommended LIT-153A or LIT-930A transient limiter accessory available separately for EMI receiver input protection during high-current testing.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344535806246,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}]},{"product_id":"li-125c","title":"LI-125C","description":"\u003cp\u003e\u003cstrong\u003eCom-Power LI-125C LISN\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LI-125C operates over a frequency range of 150 kHz to 30 MHz.\u003c\/p\u003e\n\u003cp\u003eFully compliant with CISPR 16-1-2 and ANSI C63.4 standards.\u003c\/p\u003e\n\u003cp\u003eUses air-core inductors to eliminate core saturation and maintain stability.\u003c\/p\u003e\n\u003cp\u003eIncludes individual calibration with NIST traceable certificate.\u003c\/p\u003e\n\u003cp\u003eComes with a standard three-year warranty.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eDescription \u0026amp; Application\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LI-125C provides a stable, defined impedance for power line conducted emissions testing.\u003c\/p\u003e\n\u003cp\u003eIt isolates the equipment under test (EUT) from the power source to ensure repeatable measurements.\u003c\/p\u003e\n\u003cp\u003eSuitable for use in single-phase, dual-phase, and DC systems, with optional extension for 3-phase systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIncludes a pair of separately housed, single-conductor networks.\u003c\/p\u003e\n\u003cp\u003eEquipped with Superior Electric SUPERCON® shrouded sockets and matching plugs for safe, secure connections.\u003c\/p\u003e\n\u003cp\u003eBuilt with an unpainted mounting plate for effective grounding, crucial for high-leakage current scenarios.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTransient Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA transient limiter is recommended for added protection and improved measurement quality, available from Com-Power.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach unit is individually calibrated per CISPR 16-1-2 and ANSI C63.4 standards.\u003c\/p\u003e\n\u003cp\u003eSupplied with calibration certificate and detailed performance data (impedance, phase, isolation, insertion loss).\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344537542950,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/LI-125C.jpg?v=1781505020"},{"product_id":"li-150c","title":"LI-150C","description":"\u003ch2\u003e\u003csmall\u003e\u003cstrong\u003eLI-150C\u003c\/strong\u003e: LISN equipped with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50μH inductor\u003c\/strong\u003e, used for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCC, CISPR, EN, and ANSI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the frequency range \u003cstrong\u003e150 kHz – 30 MHz\u003c\/strong\u003e\u003c\/small\u003e\u003c\/h2\u003e\n\u003cp\u003eFully compliant with CISPR 16-1-2 and ANSI C63.4 standards\u003c\/p\u003e\n\u003cp\u003eUses air-core inductors to prevent saturation and variability\u003c\/p\u003e\n\u003cp\u003eIncludes individual calibration and three-year warranty\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LI-150C is a Line Impedance Stabilization Network (LISN) used for accurate, repeatable power line conducted emissions compliance testing.\u003c\/p\u003e\n\u003cp\u003eProvides stable, defined impedance and isolates the Equipment Under Test (EUT) from power source noise.\u003c\/p\u003e\n\u003cp\u003eSuitable for single-phase, dual-phase, or DC systems; supports 3-phase setups with a second unit pair.\u003c\/p\u003e\n\u003cp\u003eConstructed with high leakage-current handling and earth-ground connection features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction \u0026amp; Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIncludes separately housed single-conductor networks\u003c\/p\u003e\n\u003cp\u003eComes with color-coded SUPERCON® shrouded sockets and matching plugs\u003c\/p\u003e\n\u003cp\u003eUnpainted mounting plate enhances grounding; built for lab or industrial use\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtection \u0026amp; Calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTransient Limiter recommended for protecting instruments and reducing out-of-band emissions\u003c\/p\u003e\n\u003cp\u003eIndividually calibrated to CISPR 16-1-2 and ANSI C63.4 with complete impedance, isolation, and insertion loss data provided\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344540295462,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/LI-150C.jpg?v=1781505214"},{"product_id":"lin-120c","title":"LIN-120C","description":"\u003cp\u003e\u003cstrong\u003eCompact dual-conductor 20 A LISN with built-in transient limiter, 150 kHz to 30 MHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the most affordable Com-Power CISPR 16-1-2 \/ ANSI C63.4 LISN, with both Line and Neutral 50 µH networks integrated in a single enclosure for fast bench-top setup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal multi-configuration EUT receptacle plus IEC C20 mains input\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— accepts almost any EUT power plug without adapters; the only 1x-series LISN with a built-in switchable transient limiter (10 dB attenuation) that protects the EMI receiver during initial scans.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAir-core 50 µH inductors, 270 V\u003csub\u003eAC\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\/ 380 V\u003csub\u003eDC\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003erating, 50 Ω N-type RF port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— standard CISPR 16-1-2 V-network performance with insertion loss below 0.5 dB and isolation above 40 dB across 150 kHz to 30 MHz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFCC Part 15 \/ CISPR 32 \/ EN 55032 pre-compliance for desktop and consumer electronics\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— PCs, laptops, monitors, network equipment, A\/V receivers, and small office equipment drawing up to 20 A on standard 120 \/ 230 V\u003csub\u003eAC\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eservice.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED lighting and small SMPS qualification\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— LED drivers, fluorescent ballast electronics, low-power switching power supplies, and consumer adapters where the integrated transient limiter speeds initial debug measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEducational laboratories and EMC training programs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the entry-level LISN for university EMC instruction, in-house engineering training, and small consultancy practices building first-time CISPR 16-1-2 capability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField-service and customer-site pre-compliance work\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— lighter and more portable than separately-housed pairs (LI-125C \/ LI-150C); the dual-housed design and built-in limiter make it the go-to for EMC consultants traveling to client facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNIST-traceable individual calibration with three-year warranty\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— impedance, phase, isolation, and insertion loss data supplied with each unit; ISO 17025 accredited calibration available on request; recommended LIT-153A or LIT-930A transient limiter accessory available separately for additional out-of-band protection beyond the integrated limiter.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344541999398,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/LIN-120C.jpg?v=1781505339"},{"product_id":"li-220c","title":"LI-220C","description":"\u003cp\u003e\u003cstrong\u003eExtended-range 9 kHz to 30 MHz dual-conductor LISN, 20 A per line\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— extends measurements 16 times lower than standard 1x-series LISNs, the only single-phase Com-Power LISN that captures the 9 kHz to 150 kHz band where modern switching converters now place dominant emissions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDual 50 µH + 250 µH air-core network\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— implements CISPR 16-1-2 V-network plus the ANSI C63.4 250 µH configuration in one unit, supporting both US FCC and international CISPR-based product testing without changing instruments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated dual-conductor enclosure with universal EUT receptacle and IEC C20 mains input\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— 270 V\u003csub\u003eAC\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\/ 380 V\u003csub\u003eDC\u003c\/sub\u003e, 14 A\u003csub\u003eDC\u003c\/sub\u003e, 50 Ω N-type RF port; insertion loss below 0.5 dB above 15 kHz and isolation above 60 dB above 150 kHz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED driver and switching power supply emissions testing below 150 kHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— modern LED drivers and SMPS often operate with switching frequencies of 50–100 kHz, placing fundamental and low-order harmonics in the 9–150 kHz band that 1x-series LISNs cannot characterize.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSmart energy meters and power line communication equipment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— products operating in the CENELEC A\/B\/C\/D bands (3–148.5 kHz) for power line communication require LISN coverage starting at 9 kHz per EN 50065 and product family standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar inverters, EV charging modules, and battery management systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— renewable-energy power conversion equipment with low-frequency switching content; the 9 kHz lower limit is now mandatory for many product family standards covering this category.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMedical devices per IEC 60601-1-2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— medical imaging electronics, patient monitors, and laboratory instruments with sensitive low-frequency conducted emissions characteristics that must be qualified across the 9 kHz–30 MHz extended range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNIST-traceable individual calibration with three-year warranty\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— impedance, phase, isolation, and insertion loss data supplied with each unit; ISO 17025 accredited calibration available on request; recommended LIT-153A or LIT-930A transient limiter accessory available separately for additional EMI receiver protection during testing.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344542949670,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/LI-220C.jpg?v=1781505506"},{"product_id":"li-3100","title":"LI-3100","description":"\u003cp\u003eCom-Power LI-3100 Line Impedance Stabilization Network (LISN):\u003c\/p\u003e\n\u003cp\u003eThe LI-3100 operates from 10 kHz to 400 MHz and supports compliance testing for DO-160, FAA, MIL-STD 461F, CISPR 25, and CISPR 16-1-2 standards.\u003c\/p\u003e\n\u003cp\u003eIt is designed to handle up to 100 amps AC with forced air cooling for reliable performance.\u003c\/p\u003e\n\u003cp\u003eThe LISN uses air-core inductors to prevent saturation and ensure stable performance over time.\u003c\/p\u003e\n\u003cp\u003eIt provides defined and stable impedance while isolating the EUT from power source influences, ensuring accurate and repeatable measurements.\u003c\/p\u003e\n\u003cp\u003eThe system includes a pair of separately housed, single-conductor LISNs for use with single-phase, dual-phase, or DC power systems.\u003c\/p\u003e\n\u003cp\u003eTwo LI-3100 units can be used together to support three-phase power systems (Wye or Delta configurations).\u003c\/p\u003e\n\u003cp\u003eSuperior Electric SUPERCON® shrouded sockets are used for mains and EUT connections, with color-coded plugs provided for easy setup.\u003c\/p\u003e\n\u003cp\u003eThe LISN features an unpainted mounting plate for a secure earth ground connection, which is necessary due to high leakage current.\u003c\/p\u003e\n\u003cp\u003eEach LI-3100 is individually calibrated to RTCA DO-160, FAA, MIL-STD 461F, CISPR 25, and CISPR 16-1-2, with impedance, phase, and insertion loss data provided.\u003c\/p\u003e\n\u003cp\u003eThe device is covered by a three-year standard warranty for long-term reliability and assurance.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344543146278,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/LI-3100.jpg?v=1781505612"},{"product_id":"li-325c","title":"LI-325C","description":"\u003cp\u003eLI-325C Line Impedance Stabilization Network:\u003c\/p\u003e\n\u003cp\u003eThe LI-325C LISN operates over a frequency range of 10 kHz to 400 MHz.\u003c\/p\u003e\n\u003cp\u003eIt is fully compliant with RTCA DO-160, FAA, and MIL-STD 461 standards.\u003c\/p\u003e\n\u003cp\u003eThe unit provides stable impedance and isolates the EUT from power source effects.\u003c\/p\u003e\n\u003cp\u003eIt ensures accurate and repeatable power line conducted emissions testing.\u003c\/p\u003e\n\u003cp\u003eEach LI-325C includes a pair of single-conductor networks for flexible system use.\u003c\/p\u003e\n\u003cp\u003eA second pair can be added for compatibility with three-phase power systems.\u003c\/p\u003e\n\u003cp\u003eAir-core inductors prevent saturation and permeability variations.\u003c\/p\u003e\n\u003cp\u003eIt uses Superior Electric SUPERCON® shrouded sockets for power connections.\u003c\/p\u003e\n\u003cp\u003eColor-coded plugs for mains and EUT wiring are included for easy setup.\u003c\/p\u003e\n\u003cp\u003eThe unpainted mounting plate ensures proper grounding to earth.\u003c\/p\u003e\n\u003cp\u003eEach unit is individually calibrated with supplied impedance and loss data.\u003c\/p\u003e\n\u003cp\u003eCalibration includes a certificate for RTCA DO-160, FAA,  and MIL-STD 461 compliance.\u003c\/p\u003e\n\u003cp\u003eThe LISN is backed by a three-year warranty from Com-Power Corporation.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344545046822,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/LI-325C_4049d8d5-dc38-48b1-bdcb-38104bd23c35.jpg?v=1781505734"},{"product_id":"li-350","title":"LI-350","description":"\u003ch2\u003e\u003csmall\u003eCom-Power LI-350 LISN\u003c\/small\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLI-350 Line Impedance Stabilization Network (LISN)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for conducted emissions testing.\u003c\/p\u003e\n\u003cp\u003eIt is fully compliant with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRTCA DO-160 and MIL-STD-461 standards\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis LISN is used for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower line conducted emissions tests\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein commercial and military applications.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efrequency range is 10 kHz to 400 MHz\u003c\/strong\u003e, covering a wide spectrum for EMC measurements.\u003c\/p\u003e\n\u003cp\u003eA\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50Ω N-type female RF connector\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a stable and accurate measurement output.\u003c\/p\u003e\n\u003cp\u003eThe unit supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 amperes of current\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e480 VAC (50–400 Hz), 270 VAC (800 Hz), and 600 VDC ratings\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5 µH air-core inductors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure consistent performance without saturation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Electric SUPERCON® shrouded sockets\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallow secure connections for mains and EUT wiring.\u003c\/p\u003e\n\u003cp\u003eEach unit comes with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindividual calibration data\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethree-year warranty\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor reliability.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344549503270,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/LI-350.jpg?v=1781505874"},{"product_id":"li-400c","title":"LI-400C","description":"\u003cp\u003eThe LI-400C Line Impedance Stabilization Network provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products.\u003c\/p\u003e\n\u003cp\u003eThe LI-400C is compliant with MIL-STD 461. The LISN provides defined stable impedance and isolates the EUT from power source influences, thereby providing accurate and repeatable results.\u003c\/p\u003e\n\u003cp\u003eThe LI-400C includes one pair of, separately housed, single-conductor networks, to be installed in series with each current-carrying conductor in a single-phase, dual-phase, or DC power system.\u003c\/p\u003e\n\u003cp\u003eA second LI-400C pair can be used to accommodate 3-phase power systems (Wye or Delta configurations). The LI-400C is equipped with Superior Electric SUPERCON® shrouded sockets at the mains (power input) and EUT (power output) ports.\u003c\/p\u003e\n\u003cp\u003eThe matching color-coded plugs for connection to the mains and EUT wiring are included. This LISN uses air-core inductors to prevent saturation and permeability variation.\u003c\/p\u003e\n\u003cp\u003eThe mounting plate of the LI-400C is left unpainted in order to facilitate connection to earth ground in its installation, which is essential due to high leakage current.\u003c\/p\u003e\n\u003cp\u003eUse of a Transient Limiter for impedance matching, reduction of out-of-band emissions and transient protection for your measurement instrument is highly recommended and available from Com- Power.\u003c\/p\u003e\n\u003cp\u003eAll Com-Power LISNs are individually calibrated in compliance with the relevant requirements of MIL-STD 461. Impedance and Insertion Loss data is supplied with each unit, along with the calibration certificate.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344558186790,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/LI-400C.jpg?v=1781505987"},{"product_id":"li-4100","title":"LI-4100","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLI-4100 Line Impedance Stabilization Network (LISN)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis fully compliant with MIL-STD-461 requirements.\u003c\/p\u003e\n\u003cp\u003eIt is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCE102 conducted emissions tests\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon AC and DC power lines, covering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10 kHz to 10 MHz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eA\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 Ω N-type female RF connector\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures accurate EMI measurement output.\u003c\/p\u003e\n\u003cp\u003eThe LISN supports a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100-ampere current rating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith forced air cooling, ideal for high-power EUTs.\u003c\/p\u003e\n\u003cp\u003eEach unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindividually calibrated per MIL-STD-46\u003c\/strong\u003e1, with ISO 17025-accredited calibration available, and comes with a three-year warranty.\u003c\/p\u003e\n\u003cp\u003eThis LISN is specifically intended for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCE102 compliance testing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunder\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMIL-STD-461F\/G\u003c\/strong\u003e, making it suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emilitary, aerospace, and defense electronics EMC testin\u003c\/strong\u003eg.\u003c\/p\u003e\n\u003cp\u003eIt can also be used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epre-compliance measurements (conducted emissions, 10 kHz–10 MHz)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCISPR-based commercial standards\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere LISNs are required.\u003c\/p\u003e\n\u003cp\u003eUsers can apply it for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediagnostic and troubleshooting tasks\u003c\/strong\u003e, such as verifying power-line filter performance, locating noise sources, and evaluating EMI suppression techniques.\u003c\/p\u003e\n\u003cp\u003eWhen used in multi-conductor setups,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eit supports three-phase conducted emissions testing (Wye or Delta)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor equipment under MIL-STD-461 environments.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344567329062,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/LI-4100.jpg?v=1781506200"},{"product_id":"li-550c-for-cispr-25-cispr-16-compliant-100-khz-to-108-mhz","title":"LI-550C","description":"\u003cp\u003eThe LI-550C Line Impedance Stabilization Network (LISN) provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe LI-550C is compliant with both CISPR 25 (Automotive EMC Testing) and CISPR 16-1-2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003eThe LISN provides defined stable impedance and isolates the EUT from power source influences, thereby providing accurate and repeatable results.\u003c\/p\u003e\n\u003cp\u003eThe LI-550C includes one pair of separately housed single-conductor networks, to be installed in series with each current-carrying conductor in a single- phase, dual-phase or DC power system.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA second LI-550C pair can be used to accommodate 3-phase power systems (Wye or Delta configurations).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LI-550C is equipped with Superior Electric SUPERCON® shrouded sockets at the mains (power input) and EUT (power output) ports.\u003c\/p\u003e\n\u003cp\u003eThe matching color-coded plugs for connection to the mains and EUT wiring are included.\u003c\/p\u003e\n\u003cp\u003eThis LISN uses air-core inductors to prevent saturation and permeability variation.\u003c\/p\u003e\n\u003cp\u003eThe mounting plate of the LI-550C is left unpainted in order to facilitate connection to earth ground in its installation, which is essential due to high leakage current.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344568607014,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/LI-550C.jpg?v=1781506381"},{"product_id":"ps-400","title":"PS-400","description":"\u003cp\u003e\u003cstrong\u003eNear field probe set, 9 kHz–5 GHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— locates EMI emission sources on PCBs, cables, and enclosures during pre-compliance debugging and troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThree-probe set: H-field loop, broadband E-field, and fine-tip E-field\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— H-field loop 9 kHz–5 GHz, broadband E-field 50 kHz–5 GHz, fine-tip E-field 100 kHz–5 GHz, all in a custom storage case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePatented fine-tip E-field probe (U.S. Patent #5,132,607)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— pinpoints noise on individual IC pins and traces as narrow as 3 mils.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo-stage workflow\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the broadband stub probe finds the general hot-spot region, then the fine-tip probe isolates the exact radiating trace or pin.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eH-field loop probe for current-driven emissions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— detects magnetic fields from clock signals, serial data, switching power supplies, and transformer leakage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure leakage detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— scans seams, ventilation slots, and cable entry points to reveal slot-antenna effects and poor bonding.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDesign debugging support\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— helps diagnose impedance mismatch, transmission-line reflections, via discontinuities, and stub effects.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC (female) interface; optional PAP-501 preamplifier (10 MHz–1000 MHz, 21 dB gain)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— connects directly to a 50 Ω spectrum analyzer or EMI receiver; no calibrated test facility required.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344569786662,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/PS-400.jpg?v=1781506633"},{"product_id":"ps-500","title":"PS-500","description":"\u003cp\u003e\u003cstrong\u003eNear field probe set with contact tip, 400 Hz–5 GHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— locates EMI emission sources on PCBs, cables, and enclosures, with added direct-contact circuit measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFour-probe set: H-field loop, broadband E-field, fine-tip E-field, and contact-tip probe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— H-field loop 9 kHz–5 GHz, broadband E-field 50 kHz–5 GHz, fine-tip E-field 100 kHz–5 GHz, contact-tip 400 Hz–5 GHz, all in a custom storage case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact-tip probe for direct circuit contact\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— confirms the exact emission source via direct capacitive coupling to a trace or pin; supports up to 50 VDC on the probed circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePatented fine-tip E-field probe (U.S. Patent #5,132,607)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— pinpoints noise on individual IC pins and traces as narrow as 3 mils.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThree-stage workflow\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— broadband probe finds the hot-spot region, fine-tip probe isolates the trace or pin, and the contact tip confirms the source by direct contact.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eH-field loop probe for current-driven emissions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— detects magnetic fields from clock signals, serial data, switching power supplies, and transformer leakage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtended low-frequency reach (400 Hz)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— the contact tip enhances power-integrity investigations beyond the PS-400 range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC (female) interface; optional PAP-501 preamplifier (10 MHz–1000 MHz, 21 dB gain)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— connects directly to a 50 Ω spectrum analyzer, EMI receiver, or oscilloscope; no calibrated test facility required.\u003c\/p\u003e","brand":"Com-Power","offers":[{"title":"Default Title","offer_id":53344569917734,"sku":null,"price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/PS-500.jpg?v=1781506725"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/collections\/dApSZ_7259f034-cfc9-49f4-b420-e376eda01ca9.jpg?v=1783479454","url":"https:\/\/nplab.shop\/collections\/com-power.oembed?page=2","provider":"NP LAB","version":"1.0","type":"link"}