{"title":"Calibration Bath","description":"\u003cp\u003eMicro-baths, compact, deep-well, refrigerated and high-temperature calibration baths.\u003c\/p\u003e","products":[{"product_id":"6102-7102-7103-micro-bath","title":"6102\/7102\/7103 Micro-Bath","description":"\u003cp\u003eHart Scientific manufactures these Micro-Baths for calibration of thermometers and sensors that do not fit in block calibrators.\u003c\/p\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePortable and extremely stable\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eNeed portability and extreme stability? Fluke Calibration Micro-Baths have both. We invented the Micro-Bath. And, while many have tried to duplicate it, none of them use proprietary Fluke Calibration controllers, so none of them deliver performance like a Fluke Calibration bath. Micro-Baths can be used anywhere for any type of sensor. The 6102 weighs less than 4.5 kg (10 lb.), with the fluid. It’s lighter and smaller than most dry-wells, has a spill-proof lid, and is easier to carry than your lunch. You can take it where you need to go without carts or excessive effort. Micro-Baths can even be transported with the fluid in them.\u003c\/p\u003e\u003cp\u003eWherever you go with your Micro-Bath, you can count on its performance. Each model is stable to ±0.03 °C or better, depending on the fluid you use. Uniformity is ±0.02 °C or better for low uncertainties using a reference thermometer. Display accuracy has been improved to ±0.25 °C for quick calibrations without a reference thermometer. In short, you get the stability and precision of a liquid bath in a dry-well-sized package. Don’t be fooled by competitors who pour oil into a dry-well and call it a bath. Micro-Baths are maximized for true fluid-bath performance.\u003c\/p\u003e\u003cp\u003eWith a 48 mm (1.9-inch) diameter, 140 mm (5.5-inch) deep tank, a Micro-Bath can calibrate any type of sensor including short, square, or odd-shaped sensors. The problems of fit and immersion are virtually eliminated by using a fluid medium rather than a dry-block calibrator. Micro-Baths are perfect for liquid-in-glass and bimetal thermometers.\u003c\/p\u003e\u003cp\u003eThe 6102 has a temperature range from 35 °C to 200 °C, the 7102 covers –5 °C to 125 °C, and the 7103 extends from –30 °C to 125 °C. Stability, uniformity, and accuracy specifications cover the entire range for each bath, not just the best temperature.\u003c\/p\u003e\u003cp\u003eAll Micro-Baths have RS-232 ports and can be used with MET\/TEMP II software (described on page 81). Also included are contacts to calibrate a thermal switch, eight set-point memory storage, ramp-rate adjust, and over-temperature safety cutout.\u003c\/p\u003e\u003cp\u003eYou may have noticed we haven’t touted our CFC-free refrigeration. Yes, cold Micro-Baths are CFC-free, and also compressor-free. That’s right—no heavy, noisy compressor to lug around. We achieve our temperature range and stability with only one moving part. This means more durability and less weight. Fluke Calibration manufactures and sells temperature calibration baths of every size and shape, and now we have the smallest and lightest baths in the industry to go with the dozens of other models we make.\u003c\/p\u003e\u003cp\u003eLook at the specs, price, and value of these portable instruments and you’ll know why Fluke Calibration is the number-one company in this business.\u003c\/p\u003e\u003cdiv\u003eModels\u003cul\u003e\n\u003cli\u003e6102\u003c\/li\u003e\n\u003cli\u003e7102\u003c\/li\u003e\n\u003cli\u003e7103\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke Calibration 6102\/7102\/7103 Micro-Bath\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecifications\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6102\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7102\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7103\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e35°C to 200°C (95°F to 392°F)\u003c\/td\u003e\n\u003ctd\u003e–5°C to 125°C (23°F to 257°F)\u003c\/td\u003e\n\u003ctd\u003e–30°C to 125°C (–22°F to 257°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.25°C\u003c\/td\u003e\n\u003ctd\u003e±0.25°C\u003c\/td\u003e\n\u003ctd\u003e±0.25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.02°C at 100°C (oil 5013)\u003cbr\u003e±0.03°C at 200°C (oil 5013)\u003c\/td\u003e\n\u003ctd\u003e±0.015°C at –5°C (oil 5010)\u003cbr\u003e±0.03°C at 121°C (oil 5010)\u003c\/td\u003e\n\u003ctd\u003e±0.03°C at –25°C (oil 5010)\u003cbr\u003e±0.05°C at 125°C (oil 5010)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniformity\u003c\/td\u003e\n\u003ctd\u003e±0.02°C\u003c\/td\u003e\n\u003ctd\u003e±0.02°C\u003c\/td\u003e\n\u003ctd\u003e±0.02°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01°C\/°F\u003c\/td\u003e\n\u003ctd\u003e0.01°C\/°F\u003c\/td\u003e\n\u003ctd\u003e0.01°C\/°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e5°C to 45°C\u003c\/td\u003e\n\u003ctd\u003e5°C to 45°C\u003c\/td\u003e\n\u003ctd\u003e5°C to 45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating time\u003c\/td\u003e\n\u003ctd\u003e25°C to 200°C: 40 minutes\u003c\/td\u003e\n\u003ctd\u003e25°C to 100°C: 30 minutes\u003c\/td\u003e\n\u003ctd\u003e25°C to 100°C: 35 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling time\u003c\/td\u003e\n\u003ctd\u003e200°C to 100°C: 35 minutes\u003c\/td\u003e\n\u003ctd\u003e25°C to 0°C: 30 minutes\u003c\/td\u003e\n\u003ctd\u003e25°C to –25°C: 45 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e64 mm dia. x 140 mm deep (2.5 x 5.5 in) (working area is 48 mm [1.9 in] in diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e14 x 26 x 20 cm\u003cbr\u003e(5.5 x 10.38 x 8 in)\u003c\/td\u003e\n\u003ctd\u003e18 x 31 x 24 cm\u003cbr\u003e(7.2 x 12 x 9.5 in)\u003c\/td\u003e\n\u003ctd\u003e23 x 34 x 26 cm\u003cbr\u003e(9 x 13.2 x 10.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.5 kg (10 lb) with fluid\u003c\/td\u003e\n\u003ctd\u003e6.8 kg (15 lb) with fluid\u003c\/td\u003e\n\u003ctd\u003e9.8 kg (22 lb) with fluid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume\u003c\/td\u003e\n\u003ctd\u003e0.75 L (1.6 pints)\u003c\/td\u003e\n\u003ctd\u003e0.75 L (1.6 pints)\u003c\/td\u003e\n\u003ctd\u003e1.0 L (2.11 pints)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e115 V AC (±10%), 2.3 A or 230 V AC (±10%), 1.1 A, switchable, 50\/60 Hz, 270 W\u003c\/td\u003e\n\u003ctd\u003e115 V AC (±10%), 1.8 A or 230 V AC (±10%), 0.9 A, switchable, 50\/60 Hz, 200 W\u003c\/td\u003e\n\u003ctd\u003e94–234 V AC (±10%), 50\/60 Hz, 400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComputer interface\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eRS-232 included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNIST-traceable calibration\u003c\/td\u003e\n\u003ctd\u003eData at 50°C, 100°C, 150°C, and 200°C\u003c\/td\u003e\n\u003ctd\u003eData at –5°C, 25°C, 55°C, 90°C, and 121°C\u003c\/td\u003e\n\u003ctd\u003eData at –25°C, 0°C, 25°C, 50°C, 75°C, 100°C, and 125°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"models-label\" class=\"tab-pane\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"6102","offer_id":54038936944934,"sku":"6102","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7102","offer_id":54038937043238,"sku":"7102","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7103","offer_id":54038937076006,"sku":"7103","price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/a310d5fa-1b1e-48c5-a73b-b108002c7761_original__size.jpg?v=1791380691"},{"product_id":"6109a-7109a-portable-calibration-bath","title":"6109A\/7109A Portable Calibration Bath","description":"\u003cp\u003eThe Fluke Calibration 6109A and 7109A Portable Calibration Baths let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other baths in this class.\u003c\/p\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003ch2\u003e\u003cstrong\u003eFour times more calibration throughput with twice the accuracy of Micro-Baths and dry-block calibrators\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\u003cbr\u003eProcess manufacturing plants for pharmaceuticals, biotechnology, and food production utilize many sanitary temperature sensors that require regular calibration. Production must stop while the calibrations are taking place. Therefore, more calibration throughput means less plant downtime. And in businesses where even a few tenths of a degree Celsius can cost thousands of dollars in ruined product, temperature accuracy is crucial to maintaining quality.\u003c\/p\u003e\u003cp\u003eThe Fluke Calibration 6109A and 7109A Portable Calibration Baths let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other baths in this class. Up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges.\u003c\/p\u003e\u003cp\u003eTwo bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe.\u003c\/p\u003e\u003cp\u003eProfessionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.\u003c\/p\u003e\u003cp\u003eFacilities managers who need to meet U.S. FDA and ISO clean room standards like the baths’ stainless steel casing that stands up to harsh cleaning solutions. They depend on the 6109A and 7109A to help maintain the accuracy of the plant’s temperature sensors, thus reducing the possibility of an expensive product batch loss.\u003c\/p\u003e\u003cp\u003eProduction engineers also appreciate the baths’ accuracy, which helps them control sensor out-of-tolerance conditions. Moreover, they prefer to use a bath designed specifically for clean room calibration throughput. No more need to make do with equipment designed for some other application.\u003c\/p\u003e\u003cp\u003eCalibration technicians who perform calibrations on platforms, in crawl spaces, and other hard-to-reach parts of the plant enjoy the portability and clean room compatibility (i.e. easy to sanitize, don’t harbor bacteria) of these baths.\u003c\/p\u003e\u003cp\u003eGlobal Fluke Calibration service and support ensure that your 6109A and 7109A baths will give you years of service that you can trust.\u003c\/p\u003e\u003ch2\u003e\u003cstrong\u003eCalibrate more sanitary sensors at a time – with confidence\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\u003cbr\u003eThe 6109A and 7109A baths calibrate most temperature sensor applications used in clean process manufacturing, including pharmaceutical bioreactors (-10 C to 100 °C), chemical reactors (200 °C), steam-in-place process (122 °C to 140 °C), autoclave sterilization (120 °C to 135 °C), food storage freezers (-25 °C), and food processing (0 °C to 220 °C).\u003c\/p\u003e\u003cp\u003eA large tank volume (112 mm square tank opening x 154 mm depth) lets you immerse up to four sanitary sensors at the same time. Calibrate a batch of odd shaped sensors of varying lengths and diameters, and still have room for a reference thermometer. Fast heating and cooling times let you get the job done without spending a lot of time waiting for the bath to come to temperature and stabilize. Increase your sanitary sensor calibration throughput and decrease expensive production downtime.\u003c\/p\u003e\u003cp\u003eExcellent system display accuracy of ± 0.1 °C. Accuracy covers all sources of error including calibration uncertainty, stability, uniformity, and repeatability. Accredited calibration is included standard. Fluke Calibration’s high metrological standards and conservative specifications mean you can have confidence in the measurements you make with the 6109A and 7109A Portable Calibration Baths.\u003c\/p\u003e\u003ch2\u003e\u003cstrong\u003eTake these portable baths almost anywhere, including the clean room\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\u003cbr\u003eThe 6109A weighs 16 kilograms (35 pounds) and the 7109A weighs 20 kilograms (44 pounds). They each feature a fixed, non-rotating bail handle, enabling most people to carry a bath with one hand. Single-handed carrying comes in handy when the job includes walking up and down stairs, across catwalks, and into other hard-to-reach environments. Two recessed handles on the bottom of each bath also make it easy to move from a shelf to a cart or benchtop. A sealed lid protects against fluid spills while moving the bath.\u003c\/p\u003e\u003cp\u003eStainless steel casing stands up to the harsh chemicals used to sterilize equipment for clean room use. Synthetic materials used for decals, keypads and feet do not harbor bacteria. The keypad is sealed against moisture ingress to protect against damage during cleaning or in non-controlled environments.\u003c\/p\u003e\u003ch2\u003e\u003cstrong\u003eEasy to use and maintain\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\u003cbr\u003eEach bath features a large color display that indicates date and time, bath fluid temperature, setpoint temperature, control indicator when the fluid is at setpoint, and heating status. A ready indicator changes color from amber to green, giving you 360-degree visual indication when the bath fluid has reached its setpoint temperature and is ready for you to start making measurements.\u003c\/p\u003e\u003cp\u003eA hot warning indicator lights up if the fluid temperature reaches above 60 °C, warning the operator that the bath fluid and tank area are hot and should not be touched.\u003c\/p\u003e\u003cp\u003eAn adjustable probe fixture holds up to four tri-clamp sensors securely inside the tank opening during calibration. An optional single probe clamp kit holds a reference probe.\u003c\/p\u003e\u003cp\u003eFluid spills create mess and potential safety hazards. The 6109A and 7109A include an overflow tube that directs excess bath fluid into an optional overflow container. A drain tube makes it easy to remove bath fluid for replacement or transport.\u003c\/p\u003e\u003ch2\u003e\u003cstrong\u003eI own a Fluke Calibration Micro-Bath. Why do I need a 6109A or 7109A bath?\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\u003cbr\u003eIf you already own a Fluke Calibration Micro-Bath or dry-block calibrator, thank you for being a customer! We hope you are enjoying the portability and stability of these popular products.\u003c\/p\u003e\u003cp\u003eHowever, there are a few reasons why you should consider adding a 6109A or 7109A bath:\u003c\/p\u003e\u003cp\u003eErrors of just a few tenths of a degree Celsius can cause expensive losses in ruined product. The 6109A and 7109A baths are twice as accurate as a Micro-Bath, helping you to reduce this risk. The 6109A and 7109A have four times the calibration throughput of a Micro-Bath, which can only calibrate a single tri-clamp sensor at a time. They're made with materials that don't harbor bacteria. Their stainless steel panels and tank are easy to clean and rust resistant--perfect for clean room use. We hope you will continue to use your Fluke Calibration Micro-Bath for many years to come. The 6109A or 7109A baths will also serve you well if you need the throughput, accuracy, and clean room readiness that they provide.\u003c\/p\u003e\u003ch2\u003e\u003cstrong\u003eBacked by global Fluke support and service\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\u003cbr\u003eThe 6109A and 7109A are designed to meet demanding Fluke Calibration metrology specifications, so you can trust that they will perform the way we say they will. Need assistance? We offer world-class support both before and after the sale, via online chat, email, telephone and through our service organizations. Rest easy knowing the value of your investment will be preserved now and into the future.\u003cbr\u003e\u003cbr\u003e \u003c\/p\u003e\u003cdiv\u003eModels\u003cul\u003e\n\u003cli\u003e6109A\u003c\/li\u003e\n\u003cli\u003e7109A\u003c\/li\u003e\n\u003cli\u003e6109A-P\u003c\/li\u003e\n\u003cli\u003e7109A-P\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke Calibration 6109A \/ 7109A Portable Calibration Baths\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003eHeight: 382 mm (15 in)\u003cbr\u003eWidth: 242 mm (9.5 in)\u003cbr\u003eDepth: 400 mm (15.7 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6109A: 16 kg (35 lb)\u003cbr\u003e7109A: 20 kg (44 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluid volume\u003c\/td\u003e\n\u003ctd\u003e2.5 liters (0.66 gallons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluid working area\u003c\/td\u003e\n\u003ctd\u003e75 mm x 75 mm (3 in x 3 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum fluid depth\u003c\/td\u003e\n\u003ctd\u003e154 mm (6.1 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory calibration\u003c\/td\u003e\n\u003ctd\u003eTraceable accredited calibration included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTemperature specifications\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003eThe temperature specifications describe the Absolute Instrumental Uncertainty at 95 % level of confidence (coverage factor k = 2) within one year from calibration. The specifications include environmental temperature effects from 13 °C to 33 °C.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e6109A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7109A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange (at 25 °C ambient temperature)\u003c\/td\u003e\n\u003ctd\u003e35 °C to 250 °C\u003c\/td\u003e\n\u003ctd\u003e–25 °C to 140 °C (–15 °C cover off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (maximum permissible error)\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 °, 0.001°\u003c\/td\u003e\n\u003ctd\u003e0.01 °, 0.001°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e0.015 °C\u003c\/td\u003e\n\u003ctd\u003e0.01 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical uniformity\u003c\/td\u003e\n\u003ctd\u003e0.03 °C up to 200 °C\u003cbr\u003e0.04 °C above 200 °C\u003c\/td\u003e\n\u003ctd\u003e0.02 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e0.04 °C\u003c\/td\u003e\n\u003ctd\u003e0.04 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical heating time\u003c\/td\u003e\n\u003ctd\u003e35 °C to 100 °C: 25 minutes\u003cbr\u003e100 °C to 250 °C: 45 minutes\u003c\/td\u003e\n\u003ctd\u003e–25 °C to 25 °C: 35 minutes\u003cbr\u003e25 °C to 140 °C: 55 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical cooling time\u003c\/td\u003e\n\u003ctd\u003e250 °C to 100 °C: 35 minutes\u003cbr\u003e100 °C to 35 °C: 55 minutes\u003c\/td\u003e\n\u003ctd\u003e140 °C to 25 °C: 45 minutes\u003cbr\u003e25 °C to –25 °C: 75 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical settling time\u003c\/td\u003e\n\u003ctd\u003e15 minutes\u003c\/td\u003e\n\u003ctd\u003e10 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"5\"\u003e\u003cstrong\u003eProcess Input Module specifications (-P models)\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"5\"\u003eThe Input Module specifications describe the Absolute Instrumental Uncertainty at 95 % level of confidence (coverage factor k = 2) within one year from calibration. The specifications include calibration uncertainty, linearity, repeatability, resolution, stability, and environmental temperature effects from 13 °C to 33 °C.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eAccuracy (Maximum Permissible Error)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference input resistance\u003c\/td\u003e\n\u003ctd\u003e0 Ω to 42 Ω\u003cbr\u003e42 Ω to 400 Ω\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.0025 Ω\u003cbr\u003e0.006 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference input temperature\u003c\/td\u003e\n\u003ctd\u003e-25 °C to 250 °C\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.007 % + 0.015 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance sensing current\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e8 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUT 4-wire resistance\u003c\/td\u003e\n\u003ctd\u003e0 Ω to 31 Ω\u003cbr\u003e31 Ω to 400 Ω\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.0025 Ω\u003cbr\u003e0.008%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUT 3-wire resistance accuracy\u003c\/td\u003e\n\u003ctd\u003e0 Ω to 400 Ω\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.12 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple mV\u003c\/td\u003e\n\u003ctd\u003e-10 mV to 100 mV\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.025 % + 0.01 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference junction temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\"\u003eThermocouple temperature\u003c\/td\u003e\n\u003ctd\u003e-25 °C to 250 °C\u003c\/td\u003e\n\u003ctd\u003eJ: 0.44 °C\u003cbr\u003eE: 0.44 °C\u003cbr\u003eL: 0.42 °C\u003c\/td\u003e\n\u003ctd\u003eK: 0.49 °C\u003cbr\u003eN: 0.57 °C\u003cbr\u003eU: 0.48 °C\u003c\/td\u003e\n\u003ctd\u003eT: 0.53 °C\u003cbr\u003eM: 0.48 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 °C to 250 °C\u003c\/td\u003e\n\u003ctd\u003eR: 1.92 °C\u003cbr\u003eD: 1.12 °C\u003c\/td\u003e\n\u003ctd\u003eS: 1.88 °C\u003cbr\u003eG\/W: 3.34 °C\u003c\/td\u003e\n\u003ctd\u003eC: 0.84 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emA range\u003c\/td\u003e\n\u003ctd\u003e0 mA to 22 mA\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.02 % + 0.002 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop power\u003c\/td\u003e\n\u003ctd\u003e24 V dc\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e± 6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"models-label\" class=\"tab-pane\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"6109A","offer_id":54038937698598,"sku":"6109A","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7109A","offer_id":54038937731366,"sku":"7109A","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"6109A-P","offer_id":54038937764134,"sku":"6109A-P","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7109A-P","offer_id":54038937796902,"sku":"7109A-P","price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/3f756469-4d8d-468c-b354-b108002f63cf_original__size.jpg?v=1791380711"},{"product_id":"7340-7380-compact-calibration-bath","title":"7340\/7380 Compact Temperature Calibration Bath","description":"\u003cp\u003eTemperature calibration baths from Fluke Calibration are easy to use, very stable \u0026amp; uniform at low temperatures. Request a quote today.\u003c\/p\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003ch2\u003e7340\u003c\/h2\u003e\u003cp\u003e\u003cbr\u003eWith an optional floor cart (including locking casters), your bath can easily be moved to any place you need it. (Available for the 7340). Casters included on the 7380.\u003c\/p\u003e\u003cp\u003eAlso featuring large work areas, our Model 7340 baths cover your needs for low temperature calibrations. The 7340 reaches cold temperatures to –40 °C. Below 0 °C, these baths maintain an impressive stability of ±0.005 °C with uniformities better than ±0.006 °C. No utility bath performs as well as Fluke Calibration’s compact baths below 0 °C or at critical room and body temperatures—or even at important higher temperatures such as 100 °C and 122 °C.\u003c\/p\u003e\u003ch2\u003e7380\u003c\/h2\u003e\u003cp\u003e\u003cbr\u003eFor ultracold temperatures, the 7380 reaches –80 °C quickly and maintains a two-sigma stability of ±0.006 °C when it gets there. The 7380 is a true metrology bath, not a chiller or circulator. With uniformity to ±0.008 °C, comparison calibration of temperature devices can be performed with high precision.\u003c\/p\u003e\u003cp\u003eEach bath includes an RS-232 serial interface for controlling your bath from a PC. With a Fluke Calibration thermometer readout, such as a Black Stack, and our MET\/TEMP II software, automated calibrations can run unattended.\u003c\/p\u003e\u003cp\u003eFluke Calibration doesn’t make chillers, circulators, or so-called utility baths, and utility bath manufacturers don’t make metrology baths. Use the right tools for your work and reap the best possible results. Baths from Fluke Calibration are the most stable and uniform of any you’ll find. They’ll give you results no other bath can.\u003c\/p\u003e\u003cdiv\u003eModels\u003cul\u003e\n\u003cli\u003e7340\u003c\/li\u003e\n\u003cli\u003e7380\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: 7340\/7380 Compact Temperature Calibration Baths\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e7340\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7380\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–40 °C to 150 °C\u003c\/td\u003e\n\u003ctd\u003e–80 °C to 100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.005 °C at\u003cbr\u003e–40 °C (ethanol)\u003cbr\u003e± 0.005 °C at\u003cbr\u003e25 °C (water)\u003cbr\u003e± 0.007 °C at\u003cbr\u003e150 °C (oil 5012)\u003c\/td\u003e\n\u003ctd\u003e± 0.006 °C at\u003cbr\u003e–80 °C (ethanol)\u003cbr\u003e± 0.010 °C at\u003cbr\u003e0 °C (ethanol)\u003cbr\u003e± 0.010 °C at\u003cbr\u003e100 °C (oil 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUniformity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.006 °C at\u003cbr\u003e–40 °C (ethanol)\u003cbr\u003e±0.005 °C at\u003cbr\u003e2 5 °C (water)\u003cbr\u003e±0.010 °C at\u003cbr\u003e150 °C (oil 5012)\u003c\/td\u003e\n\u003ctd\u003e±0.008 °C at\u003cbr\u003e–80 °C (ethanol)\u003cbr\u003e±0.012 °C\u003cbr\u003eat 0 °C (ethanol)\u003cbr\u003e±0.012 °C at\u003cbr\u003e100 °C (oil 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Time\u003csup\u003e†\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 minutes,\u003cbr\u003efrom 25°C\u003cbr\u003eto 150°C\u003cbr\u003e(oil 5012)\u003c\/td\u003e\n\u003ctd\u003e25 minutes,\u003cbr\u003efrom 25 °C\u003cbr\u003eto 100 °C\u003cbr\u003e(oil 5010)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 minutes,\u003cbr\u003efrom 25°C\u003cbr\u003eto –40°C\u003cbr\u003e(ethanol)\u003c\/td\u003e\n\u003ctd\u003e130 minutes,\u003cbr\u003efrom 25 °C\u003cbr\u003eto –80 °C\u003cbr\u003e(ethanol)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStabilization Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15–20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDigital display with push-button data entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSet-Point Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01°; 0.00018° in high-resolution mode\u003c\/td\u003e\n\u003ctd\u003e0.01°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Setting Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± 0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Setting Repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± 0.01 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccess Opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e94 x 172 mm (3.7 x 6.8 in)\u003c\/td\u003e\n\u003ctd\u003e86 x 114 mm (3.25 x 4.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81 x 133 mm (3.2 x 5.25 in)\u003c\/td\u003e\n\u003ctd\u003e86 x 114 mm (3 x 4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e234 mm (9.25 in)\u003c\/td\u003e\n\u003ctd\u003e178 mm (7 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWetted Parts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 V ac (±10 %), 60 Hz, 15 A or 230 V ac\u003cbr\u003e(±10 %), 50 Hz, 8 A, specify, 1400 VA\u003c\/td\u003e\n\u003ctd\u003e115 V ac (±10 %) 60 Hz, 16 A or 230 V ac\u003cbr\u003e(±10 %),50 Hz, 8 A, specify\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVolume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.2 liters (2.4 gal)\u003c\/td\u003e\n\u003ctd\u003e4 liters (1 gal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (WxDxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 x 622 x 584 mm (12 x 24.5 x 23 in) off cart; 305 x 622 x 819 mm (12 x 24.5 x 32.25 in) on cart\u003c\/td\u003e\n\u003ctd\u003e305 x 610 x 762 mm (12 x 24 x 30 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.4 kg (78 lb)\u003c\/td\u003e\n\u003ctd\u003e52 kg (115 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUse the 1586A Super-DAQ to automate temperature sensor calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e†Rated at nominal 115 V (or optional 230 V)\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"models-label\" class=\"tab-pane\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"7340","offer_id":54038937927974,"sku":"7340","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7380","offer_id":54038938059046,"sku":"7380","price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/bae08b25-29ba-47b2-b9d3-b2a5016bdd1b_original__size.jpg?v=1791380731"},{"product_id":"6331-7341-7381-deep-well-compact-bath","title":"6331\/7341\/7381 Deep-Well Compact Bath","description":"\u003cp\u003eCalibration baths from Fluke Calibration offer high stability, flexibility , and are a preferred choice of National Metrology Institutes. Contact us today for more information.\u003c\/p\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eNeed a bath with a lot of immersion depth, great stability, and a low price tag? How about one that minimizes fluid costs, changes temperatures quickly, and runs quietly?\u003c\/p\u003e\u003cp\u003eFluke Calibration's new Deep-Well Compact Bath series features four models covering temperatures from –80 °C to 300 °C.\u003c\/p\u003e\u003cp\u003eEach model includes a 457 mm (18-inch) deep tank to accommodate long-stem PRTs, SPRTs, and liquid-in-glass (LIG) thermometers. Access openings are 120 by 172 mm (4.7 in by 6.8 in) so you can calibrate many thermometers simultaneously. Yet only 15.9 liters (4.2 gallons) of fluid are needed to get all the benefits Deep-Well Compact Baths offer.\u003c\/p\u003e\u003cp\u003eUsing our own best-in-class temperature controller, these baths deliver the performance you need for confidence in your calibrations. The 7381 (–80 °C to 110 °C) features both stability and uniformity better than ±0.007 °C over its entire range. The 7341 (–45 °C to 150 °C) are stable to ±0.005 °C and uniform to ±0.007 °C at temperatures below ambient. And finally, the 6331 provides stability and uniformity from ±0.007 °C to ±0.025 °C over its range from 40 °C to 300 °C.\u003c\/p\u003e\u003cp\u003eBe sure to understand the performance of the temperature calibration equipment you buy. Some manufacturers offer only limited (and often difficult to interpret) specifications. The specifications tab includes stability and uniformity values for the entire range of each bath—and tells you what fluid we used in the measurements. If that’s still not enough, give us a call and we’ll be happy to explain anything—and share data with you.\u003c\/p\u003e\u003cp\u003eFluke Calibration's control system automatically adds refrigeration when you need to cool down quickly, and shuts down refrigeration when you need to heat up quickly. For maximum stability, refrigeration levels are automatically balanced to match the set-point temperature you’re working at.\u003c\/p\u003e\u003cp\u003eConnect any of these baths to a Fluke Calibration thermometer readout and our industry-leading MET\/TEMP II temperature calibration software, and you’ll be performing automated probe calibrations within minutes from switch-on.\u003c\/p\u003e\u003cp\u003eWant to optimize your bath for calibrating liquid-in-glass thermometers? Simple. With the optional LIG Thermometer Calibration Kit, you get an easy-to-install fluid level adapter tube that raises the meniscus of the bath fluid to within about 12 mm (0.5 in) of the top surface of the bath itself. The kit also includes a thermometer carousel that fits onto the top of the fluid level adapter tube and holds up to ten LIG thermometers in place. A magnifying scope (8X) is also available that mounts to the front of any Deep-Well Compact Bath so you can clearly see the liquid level of your thermometer against its temperature scale.\u003c\/p\u003e\u003cp\u003eLike all Fluke Calibration baths, these units come with a report of test that includes one hour of stability data and a verification of set-point accuracy. A convenient overflow reservoir captures any excess fluid resulting from fluid expansion, allowing the trapped fluid to be reused following subsequent fluid contraction. A drain is also provided for easily emptying the bath’s tank when needed.\u003c\/p\u003e\u003cdiv\u003eModels\u003cul\u003e\n\u003cli\u003e6331\u003c\/li\u003e\n\u003cli\u003e7341\u003c\/li\u003e\n\u003cli\u003e7381\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: 6331\/7341\/7381 Deep-Well Compact Baths\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e6331 35 °C to 300 °C\u003cbr\u003e7341 –45 °C to 150 °C\u003cbr\u003e7381 –80 °C to 110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e6331 ±0.007 °C at 100 °C (oil 5012)\u003cbr\u003e ±0.010 °C at 200 °C (oil 5017)\u003cbr\u003e ±0.015 °C at 300 °C (oil 5017)\u003cbr\u003e7341 ±0.005°C at –45°C (ethanol)\u003cbr\u003e ±0.005°C at 25°C (water)\u003cbr\u003e ±0.007°C at 150°C (oil 5012)\u003cbr\u003e7381 ±0.006°C at –80°C (ethanol)\u003cbr\u003e ±0.005°C at 0°C (ethanol)\u003cbr\u003e ±0.005°C at 100°C (oil 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniformity\u003c\/td\u003e\n\u003ctd\u003e6331 ±0.007 °C at 100 °C (oil 5012)\u003cbr\u003e ±0.017 °C at 200 °C (oil 5017)\u003cbr\u003e ±0.025 °C at 300 °C (oil 5017)\u003cbr\u003e7341 ±0.007 °C at –45 °C (ethanol)\u003cbr\u003e ±0.007 °C at 25 °C (water)\u003cbr\u003e ±0.010 °C at 150 °C (oil 5012)\u003cbr\u003e7381 ±0.007 °C at –80 °C (ethanol)\u003cbr\u003e ±0.007 °C at 0 °C (ethanol)\u003cbr\u003e ±0.007 °C at 100 °C (oil 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Time†\u003c\/td\u003e\n\u003ctd\u003e6331 130 minutes, from 40 °C to 300 °C (oil 5017)\u003cbr\u003e7341 120 minutes, from 25 °C to 150 °C (oil 5012)\u003cbr\u003e7381 60 minutes, from 25 °C to 100 °C (oil 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Time†\u003c\/td\u003e\n\u003ctd\u003e6331 14 hours, from 300 °C to 100 °C (oil 5017)\u003cbr\u003e7341 130 minutes, from 25°C to –45°C (ethanol)\u003cbr\u003e7381 210 minutes, from 25 °C to –80 °C (ethanol)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStabilization Time\u003c\/td\u003e\n\u003ctd\u003e15–20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Setting\u003c\/td\u003e\n\u003ctd\u003eDigital display with push-button data entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet-Point Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01°; 0.00018° in high-resolution mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Setting Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Setting Repeatability\u003c\/td\u003e\n\u003ctd\u003e±0.01°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Opening\u003c\/td\u003e\n\u003ctd\u003e120 x 172 mm (4.7 x 6.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e457 mm (18 in) without Liquid-in-Glass Thermometer Cal Kit\u003cbr\u003e482 mm (19 in) with Liquid-in-Glass Thermometer Cal Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted Parts\u003c\/td\u003e\n\u003ctd\u003e304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower†\u003c\/td\u003e\n\u003ctd\u003e6331 115 VAC (±10 %), 50\/60 Hz, 14.8 A or\u003cbr\u003e 230 VAC (±10 %), 50\/60 Hz, 7.4 A, specify\u003cbr\u003e7341 115 VAC (±10 %), 60 Hz, 16 A or\u003cbr\u003e 230 VAC (±10 %), 50 Hz, 8 A, specify\u003cbr\u003e7381 230 VAC (±10 %), 50 or 60 Hz, specify, 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume\u003c\/td\u003e\n\u003ctd\u003e15.9 liters (4.2 gal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e1067 x 356 x 788 mm (940 mm from floor to tank access opening) [42 x 14 x 31 in (37 in from floor to tank access opening)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6331 41 kg (90 lb.)\u003cbr\u003e7341 68 kg (150 lb.)\u003cbr\u003e7381 91 kg (200 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation\u003c\/td\u003e\n\u003ctd\u003eUse the 1586A Super-DAQ to automate temperature sensor calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e†Rated at nominal 115 V (or optional 230 V)\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"models-label\" class=\"tab-pane\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"6331","offer_id":54038938124582,"sku":"6331","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7341","offer_id":54038938190118,"sku":"7341","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7381","offer_id":54038938222886,"sku":"7381","price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/a01000b3-1607-4730-b595-b3070171deda_original__size.jpg?v=1791380740"},{"product_id":"6020-high-temperature-calibration-bath","title":"6020 High Temperature Calibration Oil Bath","description":"\u003cp\u003eThe Fluke Calibration 6020 oil bath provides stable and uniform heat sources for temperature calibrations up to 300°C with high capacity and excellent stability.\u003c\/p\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eComparison calibrations require a heat source that’s stable and uniform, and for moderately high temperatures nothing provides a better heat source than a Fluke Calibration oil bath.\u003c\/p\u003e\u003cp\u003eFluke Calibration oil baths are stable to ±0.001 °C and do not require calibration blocks or use of special calibration techniques to achieve that stability. The specifications of all our baths are “true specifications representing the performance you can expect to achieve in your lab under your operating conditions. Other companies advertise specs that they know you will never see in your lab. When their baths fail to perform, they blame it on you.\u003c\/p\u003e\u003cp\u003eFluke Calibration baths are built using a unique tank design that guarantees the best uniformity possible in a liquid bath. This, coupled with the industry’s best-selling digital bath controller, achieves uncompromised performance and ease of use.\u003c\/p\u003e\u003cp\u003eNot only does our digital controller have features like its “Super-Tweak high-resolution mode so you can dial in the exact temperatures you want, it also lets you completely automate the calibration process using your PC and our 9938 MET\/TEMP II software.\u003c\/p\u003e\u003cp\u003eYou’ll love these baths, and once you’ve got one you’ll never buy anything else. There’s a bath to match any temperature range, depth, price, and performance you need.\u003c\/p\u003e\u003cdiv\u003eModels\u003cul\u003e\u003cli\u003e6020\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: 6020 High Temperature Calibration Oil Bath\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 °C to 300 °C\u003csup\u003e†\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.001 °C at 40 °C (water)\u003cbr\u003e±0.003 °C at 100 °C (oil 5012)\u003cbr\u003e±0.005 °C at 300 °C (oil 5017)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUniformity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.002 °C at 40 °C (water)\u003cbr\u003e±0.004 °C at 100 °C (oil 5012)\u003cbr\u003e±0.012 °C at 300 °C (oil 5017)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital display with push-button data entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSet-Point Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 °C; high-resolution mode, 0.00018 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.01 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Setting Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Setting Repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.02 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeaters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 and 1050 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eAccess Opening\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(call for custom openings)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e127 x 254 mm (5 x 10 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 mm (12 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWetted Parts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 VAC (±10 %), 50\/60 Hz, 10 A or 230 VAC (±10 %), 50\/60 Hz, 5 A, specify\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVolume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27 liters (7.2 gallons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 kg (70 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (HxWxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e648 x 406 x 508 mm (25.5 x 16 x 20 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\n\u003csup\u003e†\u003c\/sup\u003eExternal cooling required for operation below 40 °C. Cooling coils are built into the bath walls. Tubing ports are accessible at the back of the bath for circulating chilled fluid or shop air to boost cooling.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"models-label\" class=\"tab-pane\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"6020","offer_id":54038938386726,"sku":"6020","price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/8d723811-4faf-401a-b72b-b2a501187b8c_original__size.jpg?v=1791380749"},{"product_id":"6050h-salt-calibration-bath","title":"6050H Extremely High Temperature Calibration Salt Bath","description":"\u003cp\u003eFluke Calibration metrology baths are known world-wide for maintaining excellent temperature control, temperature stability (±0.002 °C) \u0026amp; uniformity (±0.005 °C).\u003c\/p\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThis model is designed for high-temperature work—up to 550 °C. Most labs use this as a salt bath for calibration of thermocouples, RTDs, and SPRTs. In fact, this bath is so good you can even do comparison calibrations of SPRTs with it. The bath is stable to ±0.005 °C or better at 300 °C.\u003c\/p\u003e\u003cp\u003eFluke Calibration is the only company that offers complete automated calibration software packages that work with the bath interface option. Our optional software is not just a data acquisition package; it actually controls the calibration, including bath temperatures.\u003c\/p\u003e\u003cp\u003eChoose the model that most closely matches your needs. These baths are compatible with salt for higher temperatures and also with oils for lower temperatures.\u003c\/p\u003e\u003cp\u003eFluke sells a complete selection of salt and fluids for your bath. You can find these here. Salt baths offer better performance and less mess than sand baths. SPRT comparison calibrations in a sand bath aren’t reliable the way they are in a Fluke Calibration salt bath.\u003c\/p\u003e\u003cp\u003eAll options, including the automation interface package, are available for the 6050H. It is the finest-quality salt bath you can buy!\u003c\/p\u003e\u003cp\u003eIf you need to reach the maximum temperature possible in a salt bath, the Fluke Calibration 6050H goes to 550 °C and is 10 to 100 times more stable than alternative calibration devices.\u003c\/p\u003e\u003cp\u003eIt is 305 mm (12 in) deep and has a 127 x 254 mm (5 x 10 in) well opening for easy access. Ports in the rear of the bath access cooling coils if you want to cool the bath rapidly with external fluids.\u003c\/p\u003e\u003cdiv\u003eModels\u003cul\u003e\u003cli\u003e6050H\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: 6050H Extremely High Temperature Calibration Salt Bath\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e180 °C to 550 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.002 °C at 200 °C (salt)\u003cbr\u003e±0.004 °C at 300 °C (salt)\u003cbr\u003e±0.008 °C at 550 °C (salt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniformity\u003c\/td\u003e\n\u003ctd\u003e±0.005 °C at 200 °C (salt)\u003cbr\u003e±0.020 °C at 550 °C (salt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Setting\u003c\/td\u003e\n\u003ctd\u003eDigital display with push-button data entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet-Point Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 °C; high-resolution mode, 0.00018 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Temperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Setting Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Setting Repeatability\u003c\/td\u003e\n\u003ctd\u003e±0.02 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeaters\u003c\/td\u003e\n\u003ctd\u003e400, 1200, and 2000 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Opening\u003c\/td\u003e\n\u003ctd\u003e127 x 254 mm (5 x 10 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e305 mm (12\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted Parts\u003c\/td\u003e\n\u003ctd\u003e304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e230 VAC (±10 %), 50\/60 Hz, 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume\u003c\/td\u003e\n\u003ctd\u003e27 liters (7.1 gal), requires 50 kg (112 lb) of bath salt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e82 kg (180 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e724 x 518 x 622 mm\u003cbr\u003e(28.5 x 20.4 x 24.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation\u003c\/td\u003e\n\u003ctd\u003eUse the 1586A Super-DAQ to automate temperature sensor calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"models-label\" class=\"tab-pane\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"6050H","offer_id":54038938812710,"sku":"6050H","price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/b411fb9b-1e52-4f70-bb14-b3070154220b_original__size.jpg?v=1791380756"},{"product_id":"6054-6055-7007-deep-well-bath","title":"6054\/6055\/7007 Deep-Well Bath","description":"\u003cp\u003eGet constant liquid levels using Fluke’s 6054\/6055\/7007 Deep-Well baths along with optional interface packages to control all settings.\u003c\/p\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe 7007 is designed for the temperature range of –5 °C to 110 °C, has built-in refrigeration, is 24 inches deep, and comes with a removable polycarbonate cover.\u003cbr\u003e\u003cbr\u003eThe 6054 covers the temperature range of 50 °C to 300 °C, is also 24 inches deep, and comes with a removable stainless steel cover.\u003cbr\u003e\u003cbr\u003eThe 6055 is engineered for the temperature range of 200 °C to 550 °C with salt and is 17 inches deep. Specific size differences and various specifications are shown in the comparison table.\u003c\/p\u003e\u003cp\u003eThe Model 6055, operating up to 550 °C, uses molten salts with a pumping system for maintaining the necessary consistent fluid level required for liquid-in-glass thermometer calibrations. A viewing channel is built into the top cover for a clear visual path to your glass thermometers.\u003c\/p\u003e\u003cp\u003eThe 6055 also has an optional thermometer carousel for holding several glass thermometers in the correct calibration position without exposing them to the hot salts in the bath. The Model 2018 Carousel is completely constructed of stainless steel and has an elevated handle for rotating your thermometers to the viewing position.\u003c\/p\u003e\u003cp\u003eThese deep-well baths are built to the same performance standards as all Fluke Calibration baths, which means you can’t find another bath that has better stability or uniformity.\u003c\/p\u003e\u003cdiv\u003eModels\u003cul\u003e\n\u003cli\u003e6054\u003c\/li\u003e\n\u003cli\u003e6055\u003c\/li\u003e\n\u003cli\u003e7007\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: 6054\/6055\/7007 Deep-Well Baths\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e7007\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6054\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6055\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–5 °C to 110 °C\u003c\/td\u003e\n\u003ctd\u003e50 °C to 300 °C\u003c\/td\u003e\n\u003ctd\u003e200 °C to 550 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.001 °C at 0 °C (water\/ethanol) \u003cbr\u003e± 0.001 °C at 25 °C (water)\u003cbr\u003e± 0.003 °C at 100 °C (oil 5012)\u003c\/td\u003e\n\u003ctd\u003e± 0.003 °C at 100 °C (oil 5012)\u003cbr\u003e± 0.005 °C at 300 °C (oil 5017)\u003c\/td\u003e\n\u003ctd\u003e± 0.003 °C at 200 °C (salt)\u003cbr\u003e± 0.01 °C at 550 °C (salt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Uniformity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.004 °C at 0 °C (ethanol)\u003cbr\u003e± 0.007 °C at 100 °C (oil 5012)\u003c\/td\u003e\n\u003ctd\u003e± 0.007 °C at 100 °C (oil 5012)\u003cbr\u003e± 0.015 °C at 300 °C (oil 5017)\u003c\/td\u003e\n\u003ctd\u003e± 0.005 °C at 200 °C (salt)\u003cbr\u003e± 0.010 °C at 550 °C (salt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eTemperature Setting\u003c\/strong\u003e \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eDigital display with push-button data entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eSet-Point Resolution\u003c\/strong\u003e \u003c\/td\u003e\n\u003ctd\u003e0.002 °C, high res. 0.00003 °C\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 °C, high res. 0.00018 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Temperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.01 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Setting Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e± 1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Setting Repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.005 °C\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± 0.01 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeaters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 to 1000 W\u003c\/td\u003e\n\u003ctd\u003e250 to 1000 W\u003c\/td\u003e\n\u003ctd\u003e260 to 2080 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cbr\u003e\u003cstrong\u003eWorking Area\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e178 mm dia. (7 in)\u003c\/td\u003e\n\u003ctd\u003e196 mm dia. (7.7 in)\u003c\/td\u003e\n\u003ctd\u003e107 mm dia. (4.2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cbr\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e24 in\u003c\/td\u003e\n\u003ctd\u003e24 in\u003c\/td\u003e\n\u003ctd\u003e24 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWetted Parts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V ac (± 10 %), 50 or 60 Hz, 15 A\u003cbr\u003e(Specify frequency, contact Fluke Calibration if CE\u003cbr\u003emark required.)\u003c\/td\u003e\n\u003ctd\u003e230 V ac (± 10 %), 50\/60 Hz,\u003cbr\u003e15 A max\u003c\/td\u003e\n\u003ctd\u003e230 V ac (± 10 %), 50\/60 Hz, 15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVolume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 liters (11.2 gal)\u003c\/td\u003e\n\u003ctd\u003e50 liters (13.2 gal)\u003c\/td\u003e\n\u003ctd\u003e19.8 liters\u003cbr\u003e(5.2 gal, 43 kg [95 lb] of bath salt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (D x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e470 x 775 x 194 mm to working surface (18.5 x 30.5 x 47 in), 1397 mm (55 in) to top of stir motor, 914 mm (36 in) to control panel\u003c\/td\u003e\n\u003ctd\u003e572 x 762 x 1219 mm to working surface (22.5 x 30 x 48 in), 1422 mm (56 in) to top of stir motor box, 914 mm (36 in) to control panel\u003c\/td\u003e\n\u003ctd\u003e572 x 775 x 1219 mm to working surface (22.5 x 30.5 x 48 in), 1524 mm (60 in) to top of stir motor box, 914 mm (36 in) to control panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDistance from Line of Sight to Top of Fluid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5 mm (3\/8 in)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15.9 mm (5\/8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomation \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eUse the 1586A Super-DAQ to automate temperature sensor calibration. For IEEE-488, add the 2001-IEEE to the automation package.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003cbr\u003e \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e70.8 kg (156 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"models-label\" class=\"tab-pane\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"6054","offer_id":54038938911014,"sku":"6054","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"6055","offer_id":54038938976550,"sku":"6055","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7007","offer_id":54038939009318,"sku":"7007","price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/0e398778-ab81-43bb-a2dd-b3070171ee39_original__size.jpg?v=1791380763"},{"product_id":"7508-7511-7512-refrigerated-calibration-bath","title":"7508\/7511\/7512 Refrigerated Temperature Calibration Bath","description":"\u003cp\u003eRefrigerated temperature calibration baths engineered for metrology with unmatched temperature stability and precision using CFC-free refrigerants\u003c\/p\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWide selection, with the best digital temperature control available\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUsed by national labs for comparison calibrations and fixed-point cell maintenance, Fluke Calibration refrigerated temperature calibration baths operate at temperatures as low as –10 °C, each built using CFC-free refrigerants. Each bath is fully automated with a bath interface package and Fluke Calibration MET\/TEMP II automation software (with future support for CalStudio), which uses computer controlled solenoid valves for precision balancing of the heating and cooling system. MET\/TEMP II performs all calibration tasks automatically with the 1586A Super-DAQ, using your PC connected via USB or RS232 interfaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eUnmatched temperature stability and precision\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eFluke Calibration baths are engineered specifically for metrology, not adapted from other lab equipment. Using proprietary hybrid analog\/digital controllers, the 7508\/7511\/7512 refrigerated calibration bath achieves high temperature stability ±0.0007 °C as well as exceptional temperature stability (±0.001 °C) and uniformity (±0.003 °C) at low temperatures down to -10 °C. Set-Point Resolution reaches 0.001 °C.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSuperior engineering for reliability, ease of use, and pain-free maintenance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eFluke Calibration refrigerated baths offer industry leading reliability and longevity, which provides simplified upkeep and consistent performance over time. The intuitive, updated user interface makes adjusting settings quick and easy, while the variety of available bath sizes allow you to calibrate a wide range of Platinum Resistance Thermometers (PRTs), thermistors, thermocouples, maintaining triple point of water cells, or even the temperature of a blackbody cone. Our cold baths utilize internal refrigeration systems to reach each bath’s coldest temperature. Heat-port technology is incorporated for efficient thermal management while balanced stirring mechanisms to eliminate temperature gradients without the need for pumps. Direct-drive stirrer motors and full fluid drainage also make for easy maintenance.\u003c\/p\u003e\u003cdiv\u003eModels\u003cul\u003e\n\u003cli\u003e7508-16\u003c\/li\u003e\n\u003cli\u003e7508-25\u003c\/li\u003e\n\u003cli\u003e7508-IR-16\u003c\/li\u003e\n\u003cli\u003e7508-IR-25\u003c\/li\u003e\n\u003cli\u003e7508-26\u003c\/li\u003e\n\u003cli\u003e7508-MAX-16\u003c\/li\u003e\n\u003cli\u003e7511-16\u003c\/li\u003e\n\u003cli\u003e7511-25\u003c\/li\u003e\n\u003cli\u003e7511-26\u003c\/li\u003e\n\u003cli\u003e7511-MAX-16\u003c\/li\u003e\n\u003cli\u003e7512-16\u003c\/li\u003e\n\u003cli\u003e7512-25\u003c\/li\u003e\n\u003cli\u003e7512-MAX-16\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: 7508\/7511\/7512 Refrigerated Temperature Calibration Baths\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e7508\u003c\/td\u003e\n\u003ctd\u003e7511\u003c\/td\u003e\n\u003ctd\u003e7512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–5 °C to 110 °C\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e–10 °C to 110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.0007 °C at 25 °C (water)\u003cbr\u003e±0.001 °C at 25 °C (mineral oil)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.0008 °C at 0 °C (ethanol)\u003cbr\u003e±0.0008 °C at 25 °C (water)\u003cbr\u003e±0.003 °C at 100 °C (oil 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniformity \u003csup\u003e*\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±0.003 °C at 25 °C (water)\u003cbr\u003e±0.004 °C at 25 °C (mineral oil)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.003 °C at 0 °C (ethanol)\u003cbr\u003e±0.003 °C at 25 °C (water)\u003cbr\u003e±0.005 °C at 100 °C (oil 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Setting\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eDigital display with push-button data entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet-Point Resolution\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.001 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.01 °C or 0.001 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Setting Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Setting Repeatability\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±0.005 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeaters\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e500 and 1000 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Opening\u003cbr\u003e(call for customs)\u003c\/td\u003e\n\u003ctd\u003e324 x 184 mm\u003cbr\u003e(12.75 x 7.25 in)\u003c\/td\u003e\n\u003ctd\u003e127 x 254 mm\u003cbr\u003e(5 x 10 in)\u003c\/td\u003e\n\u003ctd\u003e162 x 292 mm\u003cbr\u003e(6.38 x 11.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e331 mm (13 in)\u003c\/td\u003e\n\u003ctd\u003e305 mm (12 in)\u003c\/td\u003e\n\u003ctd\u003e457 mm (18 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted Parts\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e115 VAC (±10 %), 60 Hz, 12 A (1380 VA); or 230 VAC (±10 %), 50 Hz, 6.39 A (1470 VA); or 208\/230 VAC, 60 Hz, 6.39 A (1400 VA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume\u003c\/td\u003e\n\u003ctd\u003e42 liters (11.2 gal)\u003c\/td\u003e\n\u003ctd\u003e27 liters (7.2 gal)\u003c\/td\u003e\n\u003ctd\u003e42 liters (11.2 gal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e61 kg (135 lb)\u003c\/td\u003e\n\u003ctd\u003e56.7 kg (125 lb)\u003c\/td\u003e\n\u003ctd\u003e68 kg (150 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e610 x 775 x 483 mm\u003cbr\u003e(24 x 30.5 x 19 in)\u003c\/td\u003e\n\u003ctd\u003e559 x 686 x 401 mm\u003cbr\u003e(22 x 27 x 15.8 in)\u003c\/td\u003e\n\u003ctd\u003e762 x 686 x 401 mm\u003cbr\u003e(30 x 27 x 15.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eUse the 1586A Super-DAQ to automate temperature sensor calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eRS-232 + USB A\/B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eColor LCD MODULE,TFT,4.3 IN DIAG,480XRGBX272 PIXELS,LED BACKLIGHT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eR290 Propane (A3 flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"4\"\u003e\n\u003csup\u003e*\u003c\/sup\u003e For 7511 and 7512, working zone definition applies as defined in the user manual\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv role=\"tabpanel\" aria-labelledby=\"models-label\" class=\"tab-pane\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"7508-16","offer_id":54038939173158,"sku":"7508-16","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7508-25","offer_id":54038939271462,"sku":"7508-25","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7508-IR-16","offer_id":54038939304230,"sku":"7508-IR-16","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7508-IR-25","offer_id":54038939336998,"sku":"7508-IR-25","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7508-26","offer_id":54038939369766,"sku":"7508-26","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7508-MAX-16","offer_id":54038939402534,"sku":"7508-MAX-16","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7511-16","offer_id":54038939435302,"sku":"7511-16","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7511-25","offer_id":54038939468070,"sku":"7511-25","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7511-26","offer_id":54038939500838,"sku":"7511-26","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7511-MAX-16","offer_id":54038939533606,"sku":"7511-MAX-16","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7512-16","offer_id":54038939566374,"sku":"7512-16","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7512-25","offer_id":54038939599142,"sku":"7512-25","price":0.0,"currency_code":"HKD","in_stock":true},{"title":"7512-MAX-16","offer_id":54038939631910,"sku":"7512-MAX-16","price":0.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/9797\/0214\/files\/a5ea4d49-6cc6-4c56-8700-b3e901591df3_original__size.jpg?v=1791380783"}],"url":"https:\/\/nplab.shop\/collections\/calibration-bath.oembed","provider":"NP LAB","version":"1.0","type":"link"}